background image

1. These instructions are best followed on a full ice bin with at

least 3 inches of ice resting against the brass thermal well.
The machine must be running to perform this adjustment;
follow step two if the machine is off.

2. Turn the thermostat adjustment screw clockwise until it

stops; this is the max cold setting and will prevent the
machine from shutting off.

3. Hold a minimum of 3 inches of ice against the middle of the

brass thermal well for 3-4 minutes. It is imperative that
enough ice be used for the

4. Slowly turn the adjustment screw counter- clockwise until the

machine shuts off. If the screw is turned too quickly, the
thermostat could be set to too warm a temperature. Turn
slowly.

5. Remove the ice from the well and warm the brass with your hand; the machine should turn

back on.

The ice machine is now set for ambient conditions. If the ice machine location experiences 
significant changes in ambient temperatures, this procedure will need to be followed again. 
Adjustments are not covered under warranty. 

© Supera    

September 2015           

       

1

1

Summary of Contents for UIM-240FA

Page 1: ...MANUAL This manual contains important information regarding your Supera unit Please read this manual thoroughly prior to equipment set up operation and maintenance Failure to comply with regular maint...

Page 2: ...one 866 953 3288 E mail Service SuperaCo com Any service communication must include Model Serial Number A detailed explanation of the issue Keep this manual for future reference The Supera Service Par...

Page 3: ...al evidence of loss or damage must be fully described and noted on your freight bill or express receipt and signed by the carrier s agent The claim should be filed on a form available from the carrier...

Page 4: ...vidually to a floor drain The use of condensate pumps for draining water is not recommended by Supera Supera assumes no responsibility for improperly installed equipment Note The purge drain fitting i...

Page 5: ...of an electrical fire Adjustments Level the machine within 1 8 inch in all directions Check the bin control for proper adjustment Check the water in the water trough for proper level Check the ice bri...

Page 6: ...tion All water supply lines must be installed per local codes Use 1 4 inch O D minimum on air cooled machines On water cooled machines 3 8 inch O D minimum tubing must be run to the condenser The wate...

Page 7: ...OFF WASH Switch is located in the control box Remove the grill screws to access the control box Note This unit does not have a splash curtain This model utilizes a thermostatic bin control in place o...

Page 8: ...This unit does not have a splash curtain This model utilizes a thermostatic bin control in place of a mechanical bin switch ON OFF WASH Switch is located in the control box Remove the grill screws to...

Page 9: ...now supplied to the water purge valve hot gas valve and the harvest motor The water purge valve opens and allows the water pump to purge the water remaining in the water trough removing impurities and...

Page 10: ...vaporators check the freeze pattern of the ice Ice should form evenly across the evaporator Bridge Thickness and Timer Adjustment Once the unit has gone through 1 or 2 harvest cycles verify that the i...

Page 11: ...e capillary tube thermo well the bin thermostat opens and the machine will shut off Bin Control Adjustment All Models Except Undercounter Models Check the bin switch for proper adjustment by swinging...

Page 12: ...the brass thermal well for 3 4 minutes It is imperative that enough ice be used for the 4 Slowly turn the adjustment screw counter clockwise until the machine shuts off If the screw is turned too qui...

Page 13: ...n 2 Check ice bridge thickness 3 Check water level in trough 4 Clean the condenser air cooled machines to insure unobstructed air flow 5 Check for leaks of any kind Water Refrigerant Oil Etc 6 Check t...

Page 14: ...move the splash curtain and inspect the evaporator and water spillway to ensure all mineral residue has been removed 8 If necessary wipe the evaporator spillway and other water transport surfaces with...

Page 15: ...urface of stainless steel that protects it from corrosion 3 Don t use cleaners that use chlorine or chlorides Don t use chlorine bleach or products like Comet to clean the steel Chlorides break down t...

Page 16: ...rvest or wait for cycle completion 3 Place the ICE OFF WASH switch to the OFF position The switch is located in the control box 4 Disconnect the tubing between the water pump discharge and water distr...

Page 17: ...Service History Model Number Serial Number Date Installed...

Page 18: ...d Under This Warranty SUPERA LLC s sole obligation under this warranty is limited to either repair or replacement of parts subject to the additional limitations below This warranty neither assumes nor...

Page 19: ...Supera Customer Care Toll Free Service Line 1 866 953 3288 For additional product and warranty information please visit our website at www SuperaCo com...

Reviews: