ADJUSTING AND MOUNTING TOOLS
The Holder A64 in
LAVINA® GEB can work with either 3 or 6 buffers
which will change its elasticity. You can make the change after
dismounting the holder as per the instruction in
TROUBLESHOOTING.
In Lavina 30GEB the holder is initially mounted with 3 buffers.
Mount the tools only after ensuring that there is enough diamond
bond material left. Be sure that the plates are
always clean before mounting.
WARNING: Always Secure the Quick Change tools with the
security plate (Fig.4.6 in red), lock with the tool holder key (Fig.4.7) and make sure that the butterfly is securely
locked at 90 degrees. Diamond tools with Velcro are attached on three foam plates (9 inch). The foam plates are
mounted on the key lock (butterfly). Always use the tool holder key (Fig.5.1).
VACUUM CONNECTION
To connect a vacuum cleaner, the Lavina 30GEB
is supplied with
vacuum hose Cam Lock inlet C250 /
vacuum hose
diam. 2,5 in (63mm)
(Fig.4.9-Position.2)
USE HORIZONTAL PROPANE TANK
The standard Lavina 30GEB is equipped with vertical propane tank with vapor draw
. If necessary the machine can
work with horizontal tank but obligatory with vapor draw. Here is how to readjust the machine for horizontal
propane tank:
Dismount the support that carries the strap holding the tank. Dismount the strap from the support. Dismount the
rear support of the tank. Remove half of the rubber insulator of the support. Place the strap in the middle of the
tank support and place again the half of the rubber insulator. This support together with the strap should be
mounted on the upper level.
Dismount the front tank support and mount it on the upper level.
Dismount the right support that has the tensioning key of the tank strap.
Mount the key on the carriage using the plate underneath and the available screws and nuts. Adjust the locking
depending on the diameter of the propane tank.
While working do not forget that you should use properly fitted tank with vapor draw, to avoid freeze regulator
problems.