General Information
900079-02J, 05/2019
Innovative Hearth Products
DRL3000 Linear Direct-Vent Gas Fireplaces
10
Figure 1 - Electronic Gas Valve
Orange Wire
(from DFC Wire
Harness)
Main Gas Inlet 3/8"
NPT
Green Wire
(from DFC Wire Harness)
Line (IN) Test Port
Manifold (OUT) Test Port
Pressure
Regulator
Tower
Yellow Ground Wire
(from DFC Wire Harness)
The SIT gas valve in this fireplace has a 3/8” NPT thread main gas inlet and outlet. Test gauge connections are
provided on the front of the electronic gas control valve (identified IN for the inlet and OUT for the manifold side).
Figure 2 - Accessing the gas valve
Glass Door Assembly
(Lower Right Corner)
Air Shutter
Adjustment Lever
Battery Backup Holder
(attached to bracket with cable)
Propane tanks are at pressures that will cause damage to valve components. Verify that the tanks have step down
regulators to reduce the pressure to safe levels.
Using a propane tank smaller than 100 lbs may create pressure loss and insufficient fuel delivery, which can cause
sooting, severe delayed ignition, or other malfunctions (see NPFA 58).
Any damage as a result of insufficient tank size or other improper installation is NOT covered under the limited
warranty.
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures
in excess of
1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during
any pressure testing of the gas supply piping system at test pressures
equal to or less than
1/2 psi (3.5 kPa).
Inlet (IN)
Manifold (OUT)
Air shutter
adjustment lever
Lower right corner
of fireplace
AIR SHUTTER AND GAS PRESSURE TEST POINTS