Installation
900079-02J, 05/2019
Innovative Hearth Products
DRL3000 Linear Direct-Vent Gas Fireplaces
45
18.
Install the Wall Switch Receiver
1.
When wall finish is complete, install the wall switch receiver in the previously installed junction box, and connect
the 2-wire terminal to the connector on the back of the receiver.
2.
Install the receiver cover plate. Ensure the receiver switch is properly aligned with the switch cover
19.
Initialize the Remote Control System
After completing the fireplace installation and before operating the fireplace, initialize the remote control system per
the instructions provided in the kit.
1.
Insert the 3-volt battery into the battery bay in the remote control
(
Figure 43
)
. Correctly align polarity (+/–).
2.
Insert the (4) provided
AA
batteries into the receiver battery bay
(
Figure 43
)
. Correctly align polarity (+/–).
Burner ON/OFF
Figure 43 - Remote and Wall Receiver Battery Compartments
Figure 44 - Remote Control Transmitter
20.
Attach the Safety-in-Operation Warning Labels
1.
Attach the furnished safety instruction labels at all fireplace operation and control points
(
Page 46
)
.
NOTE:
The installer MUST ensure these warnings are properly attached during installation. The warning labels are a
critical means of informing consumers of safe operation practices.
+
3 Volt
Battery
Compartment
Requires 4-AA 1.5V
alkaline batteries
Remote
Control
Batte
ry co
ver s
lides
on/o
ff
Slide
Switch
REMOTE
ON
OFF
Wall
Receiver
Figure 42 - Noncombustible Material with Bezel and Barrier
Surround
mounting
brackets
Clean
Face Frame
(removed first)
Bezel and Barrier
(added after Surround
- not shown)
One (1) Top non
-combustible
board
Barrier
(added after surround)
Two (2) Top
Non-combustible
boards