Installation
900079-02J, 05/2019
Innovative Hearth Products
DRL3000 Linear Direct-Vent Gas Fireplaces
50
Installing Gas Conversion Kits
WARNING
The gas supply shall be shut OFF prior to disconnecting the electrical power, before
proceeding with the conversion.
AVERTISSEMENT
Avant d’effecteur la conversion, coupez d’abord l’alimentation en gaz, ensuite, coupez
l’alimentation electrique.
1.
TURN OFF THE GAS SUPPLY TO THE FIREPLACE and disconnect power supply at the circuit breaker. Ensure
fireplace is cold.
2.
If installed, remove the surround
(
Figure 41
)
. Remove barrier.
3.
Remove the glass door
(
Page 58
)
.
4.
Remove the glass media
(
Page 61
)
.
5.
Remove the front and rear floor sections
(
Page 56
)
.
6.
Remove the two (2) screws securing the burner assembly. Remove the burner assembly with the attached
venturi tube
(
Figure 45
)
.
7.
Remove the control compartment access door and gasket
(
Figure 49
)
.
Figure 45 - Removing the Burner and Accessing the Control Compartment
Figure 46 - Removing the Air Shutter
Adjustment Rod
Control Compartment
Access Panel and Gasket
Right Burner Bracket
Remove two screws
to remove burner
assembly.
Burner
Assembly
Right Burner
Bracket
Venturi
Burner
Orifice
Air Shutter
Adjustment
Rod
8.
Refer to the instructions provided with the regulator conversion kit. Using a Torx T20 driver (with 1/4” shank)
or slotted screwdriver, remove and discard the two (2) pressure regulator mounting screws, pressure regulator
tower, the diaphragm assembly (if applicable) and the spring. Ensure the rubber gasket installed on the back of
the replacement pressure regulator is properly positioned. Discard all removed components.
9.
Install the new pressure regulator assembly using the supplied screws. Tighten the screws to 25 in. lbs.
10.
Install the enclosed identification label to the valve body where it can be easily seen.