Operation
900079-02J, 05/2019
Innovative Hearth Products
DRL3000 Linear Direct-Vent Gas Fireplaces
59
Installing the glass door
1.
Visually inspect the gasket on the backside of the glass door.
NOTE:
The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located.
Make sure the bead is not rolled into the channel at the top of the door, but remains flat against the top of the
glass.
2.
While holding the glass door by the sides, hook the top edge onto the fireplace, and swing the bottom of the
glass door gently in towards the fireplace ensuring that the gasket seats evenly as the door draws shut.
NOTE:
If the lower flange of the door does NOT clear the lower front frame of the fireplace, ensure the door
UPPER mounting flange is completely and properly engaged on the fireplace frame BEFORE INSERTING THE
SCREWS. Proper door alignment and sealing are important to the operation and performance of the fireplace.
Ensure the door seal is contacting the frame and that no air leaks are present.
3.
Align the screw holes below the glass door with the holes in the fireplace, and secure using the three (3)
provided screws
(
Figure 52
)
.
4.
For cleanface installations, install the modesty panel.
5.
Install barrier.
Removing the glass door
1.
Remove barrier.
1.
For cleanface installations, remove the modesty panel.
2.
Remove the three (3) screws beneath the door
(
Figure 52
)
.
3.
Swing the bottom of the glass door away from the fireplace to a 45° angle.
4.
Carefully grip the door at the top and bottom, and remove it from the fireplace. Place the door in a safe location
for later reinstallation.
Figure 52 - Glass Door
Glass Door
Rating plate and lighting instructions
are attached to door bracket.
NOTICE: All DRL3000 model fireplaces
include a barrier to reduce the risk of burns
from hot viewing glass. This barrier in the
fireplace is a screen shown to the right.
42” Barrier J7427
54” Barrier J7426