Operation
900079-02J, 05/2019
Innovative Hearth Products
DRL3000 Linear Direct-Vent Gas Fireplaces
61
Inspecting the glass gasket
Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities,
and seated firmly.
Cleaning the control compartment
Keep the control compartment clean by vacuuming or brushing it out at least twice a year. More frequent cleaning
may be required due to excessive lint from carpeting, bedding material, etcetera. It is imperative that control
compartments, burners and circulating air passageways of the appliance be kept clean.
Touching up paint in small areas
Only use an approved paint kit for any touch-ups. Paint is available at your local IHP dealer. Never attempt to paint a
hot fireplace. Do not attempt to repaint the fireplace until the finish is completely cured (
Burn-in Period on
Page 54)
.
If the surface becomes stained or marred, it may be lightly sanded and touched up.
Glass Media
Removing and cleaning the glass media
CAUTION
Risk of personal injury. Allow the media to completely cool before handling.
Use a clean, dry, empty shop vac to remove glass media. Wash the media in warm, soapy water. Rinse and dry
before reinstalling.
Reinstalling the glass media
Carefully follow the placement instructions
(
Page 56
)
. This will ensure a proper flame and safe combustion.
NOTE:
Improper positioning of media can create carbon build-up and will alter the performance of the fireplace.
Replacing the media
If the media needs replacement, use only the proper replacement media from manufacturer
(
Page 63
)
.
Cleaning the burner
Carefully remove the media. Vacuum out any foreign matter on the burner (e.g., lint, carbon, etc.). Ensure the burner
ports are free of debris.
NOTE:
Improper positioning of media can create carbon build-up and will alter the performance of the fireplace.
NOTE:
It is important to ensure proper glass media placement per the manual when installing these units.. Verify
pilot flame is not obstructed. Ensure media does not fall through the pilot hole in the floor. See Verifying Appliance
Operation on
Page 38
.
Inspecting the wiring
Refer to the wiring diagram
(
Figure 28
)
.
CAUTION
When servicing controls, label all wires prior to disconnection. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
ATTENTION
Au moment de l’entretien des commandes, étiquetez tous les fils avant de les débrancher.
Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux.
Inspect and clean all wire connections. Ensure that there is no wire melting or damage. The inspection should
include:
• Terminals at the valve
• ON/OFF switch