Premier VS Infrared Heating System
Page 39
June 04, 2014
INSTALLATION –
Part 1
Corner / Mitered Reflector
Corner / Mitered Reflector Kits are used above elbow locations instead of stopping and restarting a Reflector
run to accommodate the elbow. Secure the Mitered Reflectors together using the Two (2) Corner Brackets as
shown in Figure 26. Also insert #8 x 3/8” screws at each ‘tab’ location along the top of the Reflectors.
Side Reflectors
Side Reflectors are 124” (3.15 m) long. Fasten one Side Reflector per main Reflector tightly with #8 x 3/8”
screws spaced about 18” (0.5 m) apart. Install three (3)
Side Reflector Brackets
per Side Reflector, spaced
about 48” (1.2 m) apart, using #8 x 3/8” screws. DO NOT tighten screws where Reflectors overlap. Refer to
Figure 27 on the following page for details.
Figure 26: Optional - Corner (Mitered) Reflectors
Assemble Corner Brackets to
Mitered Reflectors as shown
Mitered Reflector
sections should
overlap Standard
Reflectors by
at least 4".
Fasten Mitered Reflectors
with 4 #8 x 3/8" Screws
Assembled Sections:
Tighten
screws on Reflector Brackets at both sides.
Ensure sequence of Tight / Loose screws on Reflector run starts from this point.
Tight
screws
CR039
Mitered Reflector
Kit