8.0 TROUBLESHOOTING
DT2010098-01
All operations must be carried out when the stove is cold, in the absence of electrical current (unplug the power lead) and by
authorised personnel.
PROBLEM
CAUSE
SOLUTION
The control panel display is not lit
The stove has no power supply
Check that the power lead is plugged
into the wall and the stove
Defective power lead
Replace the power lead (use only
original spares)
Fuses blown
Check the fuses in both the plug and
on the electronic board, replacing
them if necessary. If problem persists
call an electrician
Defective control panel
Replace the control panel (use only
original spares)
Defective flat cable
Replace flat cable (use only original
spares)
Defective electronic board
Replace electronic board (use only
original spares)
External pressure reader warning
"
AL 1
" "
NO DEPR
"
Blocked flue
Check and clean the flue
Broken smoke extractor
Replace the motor (use only original
spares)
Flue system too long
Verify correct installation (see section 3)
Deteriorated door or exhaust system
linings
Check all washers and linings
Pipe insulation blocked
Dismantle and clean
Silicone piping blocked or broken
Check and/or replace piping
Defective electronic board
Replace electronic board (use only
original spares)