H07023380 / DT2000477-03
English
Description of activity
Display
FLUE GAS TEMPERATURE SENSOR
DT2011669-00
Description of activity
Display
PELLET HOPPER TEMPERATURE
DT2011667-00
WHAT TO DO
- Shut down the stove by holding the ON/OFF key down for several seconds.
- The alarm will stop.
- Wait until combustion of any pellets remaining in the grate has fi nished.
- After having cleaned the grate, restart the stove by pressing the ON/OFF key. (The readout ALL
must no longer appear on the display. If this is not the case call the After-Sales Service Centre).
The fl ue gas sensor is connected to the electronic board. It constantly monitors the working
temperature allowing the stove to be used in all safety.
If the temperature exceeds the fi xed safety limit, the board cuts off the power supply to the
fuel-loading auger thus depriving the grate of pellets and starting the stove shutdown process.
- The readout SAFETY STOVE appears on the right display and the time (e.g.: 12:30) or the
temperature in the left display, depending on the initial settings.
- Activated in the STATE STOVE (stove status) function, the scrolling readout MASS
TEMP
(max. temp) appears on the right display and 00.0P alternating with the fl ue gas
sensor temperature on the left display.
- After approx. 30 seconds the alarm buzzer sounds (if activated).
SAFETY STOVE
PROBE SMO
WHAT TO DO
- Shut down the stove by holding the ON/OFF key down for several seconds.
- The alarm will stop.
- Call the After-Sales Service Centre.
If the sensor is momentarily or accidentally removed from its normal position, or is not
connected properly to the electronic board, the alarm is activated.
- The scrolling readout PROBE SMO (fl ue gas sensor) appears on the right display and the
time (e.g.: 12:30) or the temperature on the left display, depending on the initial settings.
- Activated in the STATE STOVE (stove status) function, the scrolling readout NO CONN
appears on the right display and 00.0P alternating with the fl ue gas sensor temperature
on the left display.
- After approx. 30 seconds the alarm buzzer sounds (if activated).
The automatic reset thermostat sensor is located on the pellet hopper and its function is to
protect the hopper from excessive changes in temperature.
If the pellet hopper temperature reaches critical levels, the thermostat cuts off the power
supply to the fuel-loading auger, thereby stopping the supply of pellets to the grate and
starting the stove shutdown process.
- The readout ALL appears on the right display and the time or the temperature on the left
display, depending on the initial settings.
- The readout “ALL” appears in the STATE STOVE (stove status) mode.
- After approx. 30 seconds the alarm buzzer sounds (if activated).