H07023380 / DT2000477-03
English
PROBLEM
CAUSE
SOLUTION
“NO ACC” stove status
Empty hopper
Fill the hopper
Grate requires cleaning
Clean the grate (see section 7.1)
Operating temperature not reached
Empty the grate and restart
Faulty glow plug (igniter)
Replace glow plug (use only original
spares)
Faulty electronic board
Replace the electronic board (use only
original spares)
Stove combustion gas safety
“ALF 2” stove status
Faulty pressure control device
Replace the faulty control device (use
only originalo spares)
Failed fi ll-in of Pellet-charging system
Check the electric connections
Stove safety device
“MASS TEMP” stove status
Blocked fl ue or fl ue gas outlet
Clean the fl ue and the outlet
Faulty electronic board
Replace the electronic board (use only
original spares)
Faulty limit temperature control sensor
Replace the control sensor (use only
original spares)
Badly positioned smoke sensor
Check that the sensor is correctly
positioned (see wiring diagram)
Incorrect parameter settings
Check parameter settings
Smoke sensor
“NO CONN” stove status
No connection between the 2-pin terminal
of the smoke sensor or the ambient
sensor and the electronic board
Check correct insertion/position of the
connector (see wiring diagram)
Faulty electronic board
Replace the electronic board (use only
original spares)
Badly positioned smoke sensor
Check that the sensor is correctly
connected