Appliance runs for 9-10 minutes and then
goes out
Heat sensor locked
Repeat ignition procedure. If the problem
persists, contact an authorised technician
Combustion gases have not reached the
required ignition temperature
Repeat ignition procedure. If the problem
persists, contact an authorised technician
Heat sensor badly connected
Check the wiring and connections
Blocked fl ue
Clean fl ue system
Failed ignition
See “NO ACC”
Faulty electronic board
Replace the electronic board (use only
original spares)
Pellet-charging system blocked
Empty the pellet hopper; check and
clean the auger and chute