10
POWER INPUT
The dc input power is connected to pins 5 and 6 of the power connector.
Pin 5 [Vm(+)] is the power supply plus (+) connection and pin 6 [Vom(-)]
is the power supply minus (-) connection.
An unregulated supply similar to that shown in Figure 3.4 is
preferable. If a regulated supply is used, it must be a linear
regulated supply and must be capable of operating with the added
filter capacitor. A switching regulated supply is not recommended
for use with this drive. It is important that capacitor (C1) be
connected within three feet (0.9 meter) of the input terminals. The
capacitor must be of the correct value and have the proper current
and voltage parameters (see list of components on page 11).
It is recommended that the power supply leads be twisted together (6
twists per foot).
NOTE:
If the power supply is grounded, it must only be grounded
on the negative side or the short circuit protection will not
operate properly.
NOTES:
The cable between the filter capacitor (C1) and the drive
should be twisted (six twists per foot). Maximum wire
length is three feet.
Use #16 AWG or larger wire.
Figure 3.4
Typical Power Supply For A Single Drive Application
Summary of Contents for SLO-SYN SS2000MD7
Page 1: ...INSTALLATION INSTRUCTIONS for SLO SYN MODELS SS2000MD7 SS2000MD7 128 TRANSLATOR DRIVE ...
Page 17: ...17 Suggested Methods For Control Interface Figure 4 2 ...
Page 20: ...20 M062 LE09 MOTOR 3 AMPERES SERIES CONNECTION M062 LE09 MOTOR 6 AMPERES PARALLEL CONNECTION ...
Page 21: ...21 M063 LE09 MOTOR 3 AMPERES SERIES CONNECTION M063 LE09 MOTOR 6 AMPERES PARALLEL CONNECTION ...
Page 25: ...25 ...
Page 26: ...26 ...
Page 27: ...27 ...
Page 28: ...28 ...