12
4.3 ENVIRONMENTAL SPECIFICATIONS
Temperature
Operating ........... +32º F to +122º F
(0º C to +50º C) free air ambient, Natural Convec-
tion. Maximum heat sink temperature of 158º F
(70º C) must be maintained. Forced-air cooling
may be required.
Storage .............. -40º F to +167º F
...................... (-40º C to +75º C)
Humidity .................... 95% max. noncondensing
Altitude ...................... 10,000 feet (3048 m) max.
4.4 MOTOR COMPATIBILITY
Motor Types .............. Superior Electric M and KM Series
Frame Sizes
M Series ............ M061 (NEMA 23D) through M092 (NEMA 34)
KM series .......... KML060 (NEMA 23) through
KML093 (NEMA 34)
Number of
Connections....... 4, 6, 8
Minimum
Inductance ......... 1 millihenry
Maximum
Resistance ......... = 0.25 x Vdc Supply/I Setting
Example:
Vdc = 60 I Setting = 7
R max. = 0.25 x 60/7 = 2.1 ohms
NOTE: Maximum resistance is total of motor plus cable.
CAUTION: Do not use larger frame size motor than those listed, or
the drive may be damaged.
If a larger frame size motor must be
used, consult the factory for recommendations.
Summary of Contents for SLO-SYN SS2000MD7
Page 1: ...INSTALLATION INSTRUCTIONS for SLO SYN MODELS SS2000MD7 SS2000MD7 128 TRANSLATOR DRIVE ...
Page 17: ...17 Suggested Methods For Control Interface Figure 4 2 ...
Page 20: ...20 M062 LE09 MOTOR 3 AMPERES SERIES CONNECTION M062 LE09 MOTOR 6 AMPERES PARALLEL CONNECTION ...
Page 21: ...21 M063 LE09 MOTOR 3 AMPERES SERIES CONNECTION M063 LE09 MOTOR 6 AMPERES PARALLEL CONNECTION ...
Page 25: ...25 ...
Page 26: ...26 ...
Page 27: ...27 ...
Page 28: ...28 ...