30
Specifically:
IF MOTOR DIRECTION (CW, CCW) IS REVERSED, Check For:
Reversed connections to the Motor Connector. Reversing the
phase A
or
the phase B connections will reverse the direction of
motor rotation.
IF THE MOTOR MOTION IS ERRATIC, Check For:
Supply voltage out of tolerance.
Improper motion parameters (low speed, acceleration/decelera-
tion, jog speed, home speed and feed rate). Set parameters on
controller supplying pulse input to drive.
Filter capacitor missing or too low in value.
IF TORQUE IS LOW, Check For:
All Windings Off active or Reduced Current active.
Improper supply voltage.
IF "POWER" INDICATOR IS NOT LIT, Check For:
Improper input wiring and voltage levels
Blown supply circuit fuse or tripped input circuit breaker
IF "FAULT" INDICATOR IS LIT, Check For:
Improper motor wiring
Grounded or shorted wiring to the motor or shorted motor
Improper motor type or incorrect Current Select switch setting
Ambient temperature around drive above 50 ºC (122 ºF)
Heat sink temperature above 70 ºC (158 ºF)
Restricted airflow around drive
If a malfunction occurs that cannot be corrected by making the pre-
ceding checks, contact Superior Electric.
Summary of Contents for SLO-SYN SS2000MD7
Page 1: ...INSTALLATION INSTRUCTIONS for SLO SYN MODELS SS2000MD7 SS2000MD7 128 TRANSLATOR DRIVE ...
Page 17: ...17 Suggested Methods For Control Interface Figure 4 2 ...
Page 20: ...20 M062 LE09 MOTOR 3 AMPERES SERIES CONNECTION M062 LE09 MOTOR 6 AMPERES PARALLEL CONNECTION ...
Page 21: ...21 M063 LE09 MOTOR 3 AMPERES SERIES CONNECTION M063 LE09 MOTOR 6 AMPERES PARALLEL CONNECTION ...
Page 25: ...25 ...
Page 26: ...26 ...
Page 27: ...27 ...
Page 28: ...28 ...