Superior
PAPER HANDLING SOLUTIONS
4
© 2005-2015 Superior-PHS
RUN SCREEN
1.
Batch Size:
(1-9999) Press the display to bring up Keypad. Enter required batch size,
press enter to save and return to Run Screen.
2.
Actual Count:
Displays the count as the feeder
is running. If batch completes the display will
show “0” zero indicating the batch is done and is
waiting for next cycle signal. If feeder stops
before completing the complete batch size,
display will show the number of pieces fed until
stopped. If the feeder is stopped because of a
Double Detect Error, jog the double through and
DO NOT include in the partial batch, press cycle to restage the product. Either a cycle or
photo eye trigger will finish the batch set. All other feeder stops can be restaged and the
batch count will complete.
3.
Count Reset Button:
W
hen pressed sets Actual Count to “0” zero. You can press the
Count Reset Button at any time and the complete batch count request will re-issue.