ERROR DETECT SET-UP SCREEN
ERROR DETECT SET-UP SCREEN
1.
Miss Detect:
Miss Detect occurs when a new trigger signal or cycle signal is received
prior to finishing the current Batch Size, provided this error condition is turned ON.
Feeder and Dropper will stop and the Yellow Fault Light will flash. Press the ON/OFF
button to toggle between ON and OFF.
2.
Double Detect:
Double Detect occurs when the Double Detect Sensor is activated and
provided this error condition is turned ON. See Mechanical or Burn-Thru Double Detect
Setting Section of the manual, depending on type of Double Detect provided with feeder.
Feeder and Dropper will stop and the Yellow Fault Light will flash. Press the ON/OFF
button to toggle between ON and OFF.
3.
Time Out Detect:
Time Out Detect occurs when the feeder sheet sensor does not
change states (stays blocked or unblocked) for about 2 seconds, and provided this error
condition is turned ON. Typically used to determine if feeder runs out of product or has
a product jam. Feeder and Dropper will stop and the Yellow Fault Light will flash. Press
the ON/OFF button to toggle between ON and OFF.
4.
Up/Down Screen Arrow Buttons
: When pressed moves to the next screen.
5.
Run Screen Button
: Takes operator directly to Run Screen
6.
Dropper Screen Button:
Takes operator directly to Dropper screen.