Overheat/Fan Fail:
When this LED fl ashes, it indicates a fan failure. When on continuously it indicates
an overheat condition, which may be caused by cables obstructing the airfl ow in
the system or the ambient room temperature being too warm. Check the routing of
the cables and make sure all fans are present and operating normally. You should
also check to make sure that the chassis covers are installed. Finally, verify that
the heatsinks are installed properly (see Chapter 5). This LED will remain fl ashing
or on as long as the indicated condition exists.
NIC1
Indicates network activity on the LAN1 port when fl ashing.
NIC2
Indicates network activity on the LAN2 port when fl ashing.
Heartbeat
On the 6048R-DE2CR24L, this is a serverboard heartbeat LED and indicates that
power is being supplied to the serverboard.
Power Fail
Indicates a power supply module has failed. The second power supply module will
take the load and keep the system running but the failed module will need to be
replaced. Refer to Chapter 6 for details on replacing the power supply. This LED
should be off when the system is operating normally.
Summary of Contents for 6048R-DE2CR24L
Page 1: ...User s Manual Revision 1 0 SuperStoreSystem 6048R DE2CR24L ...
Page 5: ...Notes Preface v ...
Page 10: ...SUPERSTORESYSTEM 6048R DE2CR24L User s Manual x Notes ...
Page 26: ...3 4 SUPERSTORESYSTEM 6048R DE2CR24L User s Manual Notes ...
Page 46: ...4 20 SUPERSTORESYSTEM 6048R DE2CR24L User s Manual Notes ...
Page 72: ...6 6 SUPERSTORESYSTEM 6048R DE2CR24L User s Manual Figure 6 5 Replacing Node Fans ...
Page 78: ...6 12 SUPERSTORESYSTEM 6048R DE2CR24L User s Manual Notes ...
Page 122: ...A 2 SUPERSTORESYSTEM 6048R DE2CR24L User s Manual Notes ...