Chapter 6: Advanced Chassis Setup
6-11
6-6
Power Supply: 7044H-82
The SuperServer 7044H-82 has a single 650 watt power supply. This
power supply has an auto-switching capability, which enables it to auto-
matically sense and operate at a 100V or 240V input voltage.
Power Supply Failure
If the power supply unit fails, the system will shut down and you will need
to replace the power supply unit. Replace with the same model - SP650-RP
(p/n PWS-0056), which can be ordered directly from Supermicro (see Con-
tact Information in the Preface). As there is only one power supply unit in
the 7044H-82, the server must be powered down before removing and/or
replacing the power supply for whatever reason.
Replacing the Power Supply
1.
Removing the power supply
First turn the power switch on the control panel off, then unplug the
power cord from the system. Then, unplug the power cord from the
failed power supply module. Finish by pressing the locking tab on the
module and pull the unit completely out.
2.
Installing a new power supply
Replace the failed unit with another unit having the exact same part
number (PWS-0056). Gently but firmly push the new unit all the way into
the open bay. Secure it to the chassis using the locking tab. Finish by
replacing the chassis left/top cover and then plugging the power cord
back into the new module you just added.
Summary of Contents for 7044H-82
Page 5: ...v Preface Notes ...
Page 10: ...Notes x SUPERSERVER 7044H 82R 7044H X8R 7044H 82 User s Manual ...
Page 30: ...3 4 SUPERSERVER 7044H 82R 7044H X8R 7044H 82 User s Manual Notes ...
Page 58: ...5 24 SUPERSERVER 7044H 82R 7044H X8R 7044H 82 User s Manual Notes ...
Page 70: ...6 12 SUPERSERVER 7044H 82R 7044H X8R 7044H 82 Manual Notes ...
Page 94: ...7 24 SUPERSERVER 7044H 82R 7044H X8R 7044H 82 User s Manual Notes ...
Page 100: ...A 6 SUPERSERVER 7044H 82R 7044H X8R 7044H 82 User s Manual Notes ...
Page 124: ...C 4 SUPERSERVER 7044H 82R 7044H X8R 7044H 82 User s Manual Notes ...