2-4
S
UPER
S
ERVER 7044H-T/7044H-TR User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the system into a rack unit. Rack
installation requires the use of the optional rackmount kit [CSE-PT26(B)]. If the
system has already been mounted into a rack or if you are using it as a tower, you
can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the
market, which may mean the assembly procedure will differ slightly. The following
is a guideline for installing the server into a rack with the rack rails provided in the
rackmount kit. You should also refer to the installation instructions that came with
the rack unit you are using.
Identifying the Sections of the Rack Rails
The optional rackmount kit (CSE-PT26 or CSE-PT26B - black) includes two rack
rail assemblies. Each of these assemblies consist of three sections: an inner fi xed
chassis rail that secures to the chassis, an outer rack rail that secures directly to
the rack itself and two rail brackets, which also attack to the rack (see Figure 2-1.)
The inner and outer rails must be detached from each other to install.
To remove the inner chassis rail, pull it out as far as possible - you should hear a
"click" sound as a locking tab emerges from inside the rail assembly and locks the
inner rail. Depress the locking tab to pull the inner rail completely out. Do this for
both assemblies (one for each side).
Figure 2-1. Identifying the Sections of the Rack Rails
Inner rail
Outer rail
Rail brackets
Summary of Contents for 7044H-T
Page 1: ... SUPERSERVER 7044H T SUPERSERVER 7044H TR SUPER USER S MANUAL 1 0a ...
Page 5: ...v Preface Notes ...
Page 10: ...Notes x SUPERSERVER 7044H T 7044H TR User s Manual ...
Page 30: ...3 4 SUPERSERVER 7044H T 7044H TR User s Manual Notes ...
Page 88: ...7 22 SUPERSERVER 7044H T 7044H TR User s Manual Notes ...
Page 94: ...A 6 SUPERSERVER 7044H T 7044H TR User sManual Notes ...
Page 118: ...C 4 SUPERSERVER 7044H T 7044H TR User s Manual Notes ...