Chapter 4: Chassis Setup and Maintenance
4-6 System Fans
Five heavy-duty hot-swap system fans (three mid-chassis and two rear exhaust)
provide cooling for the chassis.
Figure 4-10. Rear Exhaust Fan
Release Tab
Replacing a System Fan
1. If necessary, open the chassis while the power is running to determine which fan
has failed. (Do not run the server for an extended time with the chassis open.)
2. Remove the failed fan's power cord from the JBOD control board.
3. Press the fan release tab to lift the failed fan from the chassis and pull it
completely from the chassis.
4. Place the new fan into the vacant space in the housing making sure the arrows
on the top of the fan, indicating air direction, point in the same direction as the
arrows on the other fans.
5. Check that the fan is working properly before replacing the chassis cover.
Figure 4-9. Mid-chassis Fan
Release Tab