Supermicro CSE-LA15-W Chassis Series User's Manual
Figure 1-1. Control Panel
1.3 Chassis Features
Control Panel
Power switches and status LEDs are located on the control panel on the front of the chassis.
Control Panel Features
Item
Features
Description
1
Power button
The main power switch applies or removes primary power from the power supply to
the server but maintains standby power.
2
Reset
This button is used to 'hard reboot' the system
3
Power LED
Indicates power is being supplied to the system power supply units. This
LED is illuminated when the system is operating normally.
4
HDD
Indicates activity on the hard drive when flashing.
5
NIC LED
Indicates network activity on LAN1 when flashing.
6
NIC LED
Indicates network activity on LAN2 when flashing.
7
Information LED Alerts operator to several states, as noted in the table below.
8
UID button/LED
The unit identification (UID) button turns on or off the blue light function of the
Information LED and a blue LED on the rear of the chassis. These are used to
locate the server in large racks
Information LED
Status
Description
Continuously on and
red
An overheat condition has occurred.
(This may be caused by cable congestion.)
Blinking red (1Hz)
Fan failure, check for an inoperative fan.
Blinking red (0.25Hz)
Power failure, check for a non-operational power
supply.
Solid blue
UID has been activated locally to locate the
server in a rack environment.
Blinking blue
UID has been activated using IPMI to locate the
server in a rack environment.