 Warning!

When stranded wiring is required, use approved wiring terminations, such as 
closedloop or spade-type with upturned lugs. These terminations should be the 
appropriate size for the wires and should clamp both the insulation and conductor.

DC Power Supply 

Warnung 
Wenn Litzenverdrahtung erforderlich ist, sind zugelassene 
Verdrahtungsabschlüsse, z.B. für einen geschlossenen Regelkreis oder 

gabelförmig, mit nach oben gerichteten Kabelschuhen zu verwenden. Diese 
Abschlüsse sollten die angemessene Größe für die Drähte haben und sowohl die 

Isolierung als auch den Leiter festklemmen.

¡Advertencia! 
Cuando se necesite hilo trenzado, utilizar terminales para cables homologados, 
tales como las de tipo "bucle cerrado" o "espada", con las lengüetas de conexión 
vueltas hacia arriba. Estos terminales deberán ser del tamaño apropiado para los 
cables que se utilicen, y tendrán que sujetar tanto el aislante como el conductor.

警告

需要多股佈線時,請使用經核准的佈線終端,例如閉環或鏟型接線片。 這些終端的

大小應適合線路,並且可以同時夾住絕緣體和導體。

警告

需要使用绞线连接时,请使用经认可的连接端子,如闭环端子或具有接线柱的铲形

端子。这些端子的大小应与线缆相吻合,并且可以将绝缘部分和导体夹紧固定。

Attention 
Quand des fils torsadés sont nécessaires, utiliser des douilles terminales 
homologuées telles que celles à circuit fermé ou du type à plage ouverte avec 
cosses rebroussées. Ces douilles terminales doivent être de la taille qui convient 

aux fils et doivent être refermées sur la gaine isolante et sur le conducteur.

عندما يكون مطلوبا الأسلاك الذين تقطعت بهم السبل، واستخدام الأسلاك 

إنهاء الموافقة عليها، مثل حلقة مغلقة أو الأشياء بأسمائها الحقيقية النوع 

مع العروات مقلوبة. وينبغي لهذه الإنهاءات يكون الحجم المناسب للأسلاك 

ويجب كبح كل من العزل وموصل.

Waarschuwing 
Wanneer geslagen bedrading vereist is, dient u bedrading te gebruiken die voorzien 
is van goedgekeurde aansluitingspunten, zoals het gesloten-lus type of het 
grijperschop type waarbij de aansluitpunten omhoog wijzen. Deze aansluitpunten 
dienen de juiste maat voor de draden te hebben en dienen zowel de isolatie als 
de geleider vast te klemmen

.

주의!

꼬인 배선이 요구 될 때에는 폐회로나 돌출부가 위로 튀어 나온 Spade형태의 
승인된 배선 터미네이션들을 사용하세요.

이 터미네이션들은 배선들을 위해 적절한 크기여야 하고, 절연체와 도체 모두를 
고정시킬 수 있어야 합니다.

警告

より線が必要な場合、承認済みのケーブル終端(上向きの端子を備えたクローズループ

型またはU字型の終端など)を使用してください。使用するワイヤーに適したサイズで、絶

縁体および導体が両方ともクランプされている終端でなければなりません。

Summary of Contents for SC815 series

Page 1: ... SC815TQC R706 CB WB SC815TQC R605 CB WB SC815TQC R504 CB WB SC815S R650C V B SC815TQ R650C V B SC815TQ R650U V B SC815TQ R654 CB USER S MANUAL 1 1b FRONT VIEW REAR VIEW Проконсультироваться и купить данное оборудование вы можете в компании АНД Системс адрес 125480 г Москва ул Туристская д 33 1 site https andpro ru тел 7 495 545 4870 email info andpro ru При обращении используйте промокод AND PDF ...

Page 2: ...re and documentation is the property of Supermicro and or its licensors and is supplied only under a license Any use or reproduction of this product is not allowed except as expressly permitted by the terms of said license IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUME...

Page 3: ...ow the procedures given in this chapter when installing removing or reconfiguring your chassis into a rack environment Appendices This section lists compatible cables power supply specifications and compatible backplanes Not all compatible backplanes are listed Refer to our Web site for the latest compatible backplane information Appendix A Power Supply Specifications Appendix B BPN SAS 815TQ Back...

Page 4: ...ling the Air Shroud 5 12 5 7 System Fans 5 14 5 8 Power Supply 5 16 Power Supply Failure 5 16 5 9 Routing the I2 C Cables 5 18 Chapter 6 Rack Installation 6 1 Overview 6 1 6 2 Unpacking the System 6 1 6 3 Preparing for Setup 6 1 Choosing a Setup Location 6 1 Rack Precautions 6 2 General Server Precautions 6 2 Rack Mounting Considerations 6 2 Ambient Operating Temperature 6 2 Reduced Airflow 6 3 Me...

Page 5: ...SC815 Chassis Manual viii Notes ...

Page 6: ...articular chassis model http www supermicro com Chapter 1 Introduction 1 1 SC815 Chassis Model HDD I O Slots Power Supply SC815T 563 CB UB 4x SAS SATA CB 1x FF UB 1 FH UIO 1x FF 1x LP 560W Gold Level SC815T 330 CB UB 4x SAS SATA CB 1x FF UB 1 FH UIO 1x FF 1x LP 330W Gold Level SC815TQ 720 CB UB 4x SAS SATA CB 1x FF UB 1 FH UIO 1x FF 1x LP 700W Gold Level SC815TQ 710 U B 4x SAS SATA 1 FH UIO 1x FF ...

Page 7: ...ght half length LP Low profile 1 3 Contacting Supermicro Headquarters Address Super Micro Computer Inc 980 Rock Ave San Jose CA 95131 U S A Tel 1 408 503 8000 Fax 1 408 503 8008 Email marketing supermicro com General Information support supermicro com Technical Support Website www supermicro com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel...

Page 8: ...must be mailed when service is complete For faster service RMA authorizations may be requested online http www supermicro com support rma Whenever possible repack the chassis in the original Supermicro carton using the original packaging material If these are no longer available be sure to pack the chassis securely using packaging material to surround the chassis so that it does not shift within t...

Page 9: ... or configuring components in the Supermicro chassis These warnings may also be found on our web site at http www supermicro com about policies safety_information cfm Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for pr...

Page 10: ...ent utilisées pour éviter les accidents Pour prendre connaissance des traductions des avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil référez vous au numéro de l instruction situé à la fin de chaque avertissement CONSERVEZ CES INFORMATIONS 안전을 위한 주의사항 경고 이 경고 기호는 위험이 있음을 알려 줍니다 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확...

Page 11: ...p de voedingsbron aansluit サーキッ ト ブレーカー この製品は 短絡 過電流 保護装置がある建物での設置を前提としています 保護装置の定格が60VDC 20Aを超えないこ とを確認下さい Warnung Dieses Produkt ist darauf angewiesen dass im Gebäude ein Kurzschluss bzw Überstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 60VDC 20A beträgt Advertencia Este equipo utiliza el sistema de protección contra cortocircuitos o sobrec...

Page 12: ...t beveiligde aparaat niet groter gedimensioneerd is dan 60V 20A Advertencia El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le système doit être débranché de toutes les sources de puissance ainsi que de son...

Page 13: ...רש בלבד מוסמך צוות את להחליף להתקין אי הציוד עבור שירות לתת או הציוד والمدربيه و لتزكيب استبدال أو خدمة الجهاس هذا يسمح أن يجب فقط المؤهليه للمىظفيه 경고 훈련을 받고 공인된 기술자만이 이 장비의 설치 교체 또는 서비스를 수행할 수 있습니다 Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd vervangen of hersteld door geschoold en gekwalificeerd personeel Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Z...

Page 14: ...ا مناطق محظورة تم انىص َمكن ً إن ىل منطقت محظورة فقط استخذاو خالل من خاصت أداة أو ٌ أ نال أخري وسُهت مألما ومفتاح قفم 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te maken van speciaal geree...

Page 15: ...stema está en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le système est en fonctionnement des tensions électriques circulent sur le fond de panier Prendre des précautions lors de la maintenance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing Redundant Power Supplie...

Page 16: ...וקי תואמת להיות חייבת הציוד المعدات تركيب الكهربائية لل يمتثل أن يجب قىاويه والىطىية المحلية المتعلقة بالكهرباء 경고 시스템이 동작 중일 때 후면판 Backplane 에는 위험한 전압이나 에너지가 발생 합니다 서비스 작업 시 주의하십시오 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhoud האחורי בפנל מתח אז הרה במהלך להיזהר יש המערכת תפעול בזמן ה...

Page 17: ...os ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilateur du châssis Prenez garde à ce que doigts tournevis et autres objets soient éloignés du logeme...

Page 18: ...同時夾住絕緣體和導體 警告 需要使用绞线连接时 请使用经认可的连接端子 如闭环端子或具有接线柱的铲形 端子 这些端子的大小应与线缆相吻合 并且可以将绝缘部分和导体夹紧固定 Attention Quand des fils torsadés sont nécessaires utiliser des douilles terminales homologuées telles que celles à circuit fermé ou du type à plage ouverte avec cosses rebroussées Ces douilles terminales doivent être de la taille qui convient aux fils et doivent être refermées sur la gaine isolante et sur le con...

Page 19: ...ing Wanneer geslagen bedrading vereist is dient u bedrading te gebruiken die voorzien is van goedgekeurde aansluitingspunten zoals het gesloten lus type of het grijperschop type waarbij de aansluitpunten omhoog wijzen Deze aansluitpunten dienen de juiste maat voor de draden te hebben en dienen zowel de isolatie als de geleider vast te klemmen Hazardous voltage or energy may be present on DC power ...

Page 20: ...z vous que les conducteurs non isolés ne sont pas accessibles lorsque le couvercle est en place دق دهجلا ةرطخلا وأ ةقاطلا نوكت ةدوجوم ىلع تاطحم ةقاطلا ةمصاعلا لادبتسا ءاطغ امئاد امدنع تاطحملا تسيل يف ةمدخلا امم ال كش هيف تالصوملا ريغ لوزعم ال نكمي لوصولا اهيلإ امدنع ءاطغلا يف هناكم Waarshuwing Op DC aansluitingspunten kunnen zich gevaarlijke voltages of energieën voordoen Plaats altijd de afsluiti...

Page 21: ... four fans with an optional fifth fan and one sometimes two power supplies SC815 models come in silver and black 3 2 Components Backplane Each SC815 chassis comes with a 1U backplane Your backplane supports SAS SATA For more information regarding compatible backplanes view the appendices found at the end of this manual In addition visit our website for the latest informa tion http www supermicro c...

Page 22: ...sually plastic that funnel air directly to where it is needed Always use the air shroud included with your chassis 3 3 Where to get Replacement Components Though not frequently you may need replacement parts for your system To ensure the highest level of professional service and technical support we strongly recom mend purchasing exclusively from our Supermicro Authorized Distributors System Integ...

Page 23: ...med of the overall status of the system as well as the activity and health of specific components This chapter covers these buttons and explains the meanings of all LED indicators and the appropriate responses you may need to take Figure 4 1 Chassis Control Panel Note Your control panel may differ from the control pan el pictured above See the following pages for further information ...

Page 24: ...ard the UID button is used to turn on or off the blue light function of the the U LED Once the blue light is activated the unit can be easily located in very large racks and server banks Universal Information LED The Universal Information LED is used to indated fan failure power failure overheat condition or to identify the unit within a large rack installation The feature requires a motherboard t...

Page 25: ...d 1Hz Fan failure check for an inoperative fan Blinking red 0 25Hz Power failure check for a non operational power supply Solid blue Local UID has been activated Use this function to locate the server in a rack mount environment Blinking blue 300 msec Remote UID is on Use this function to identify the server from a remote location 4 5 Power Supply LEDs and Overheat Indicators This chassis provides...

Page 26: ... to be set at 45 50 or 55 by changing a jumper setting For more information download the backplane user manual at www supermicro com To access the manuals on the Website click sup port and then click the manuals link Overheating Condition If the Server Overheats do the Following 1 Use the LEDs to determine the nature of the overheating condition 2 Confirm that the chassis covers are installed prop...

Page 27: ... chassis The only tool you will need to install components and perform maintenance is a Phillips screwdriver Print this page to use as a reference while setting up your chassis Review the warnings and precautions listed in the manual before setting up or servicing this chassis These include information in Chapter 2 System Safety and the warning precautions listed in the setup instructions ...

Page 28: ...erver without the cover in place The chassis cover must be in place to allow proper airflow and prevent overheating Figure 5 1 Removing the Chassis Cover The Front Bezel Optional If your system has an optional front bezel attached to the chassis you must remove it to access the drive bays A filter located within the bezel can be removed for cleaning or replacement It is recommended that you keep a...

Page 29: ...e mounted in drive carriers to simplify their installation and removal from the chassis These carriers also help promote proper airflow for the drive bays Figure 5 4 Chassis Drive Carrier Installing a Hard Drive to the Hard Drive Carrier 1 Remove the two screws securing the dummy drive to the carrier 2 Remove the dummy drive from the carrier Warning Except for short periods of time swapping hard d...

Page 30: ...er Figure 5 7 Replacing the Hard Drive Carrier 4 4 5 Figure 5 8 Installing the DVD Drive 5 4 Installing the DVD Drive SC815 chassis models include space for one optional DVD drive Installing the DVD Drive 1 Power down the system and unplug the power cord from the rear of the power supply Open the chassis cover as described in Section 5 3 2 Secure the left rail A to the left side of the DVD drive u...

Page 31: ...rements and precautions 2 Power down the system and remove the power cord from the rear of the power supply Remove both power cords if your system includes a redundant power supply Remove the chassis cover as described in Section 5 3 Open the chassis cover 3 If necessary remove the riser card To do this remove the two screws hold ing the card in place and lift the card from the chassis 4 As requir...

Page 32: ...ow Profile PCI Slots Installing an Expansion Card 1 Confirm that you have the correct riser card for your chassis model and the add on card includes a standard bracket 2 Remove the chassis cover 3 Install the riser card onto the bracket Insert the card and bracket into the appropriate slot on the motherboard Secure the riser bracket to the chassis using screws as illustrated 4 Choose the PCI slot ...

Page 33: ...th your left hand on the main shroud component and right hand on the optional flap b Gently twist with your right hand by lifting the fan side and lowering the other end of the optional flap 3 Place the air shroud in your chassis with the fan side touching the edge of the fans 4 Reconnect the power cord s power up the system and replace the chassis cover Checking the Airflow in the Chassis 1 Make ...

Page 34: ...board 5 Reconnect the power cord s power up the system and check that the fan is working properly before replacing the chassis cover 5 7 System Fans Figure 5 14 System Fan Figure 5 15 Chassis Fans Note additional fan options The SC815 chassis includes four pre installed fans One or two extra slots are available so that additional fans may be added Replacing a System Fan 1 If necessary open the cha...

Page 35: ... 0 25Hz LED indicator Replacement power supply units can be ordered directly from Supermicro see contact information in the Preface As there is only one power supply unit in the SC815 Chassis power must be completely removed from the server before removing and replacing the power supply unit for whatever reason 5 8 Power Supply Replacing the Power Supply 1 Power down the server and unplug the powe...

Page 36: ...s It is necessary to correctly route the I2 C cables to avoid interference due to noise on the I2 C lines Using tie wraps secure the I2 C cables to the large black power switch ing cable to keep it close to the power supply and away from the motherboard ...

Page 37: ...l noise and electromagnetic fields are generated You will also need it placed near a grounded power outlet Be sure to read the Rack and Server Pre cautions in the next section 6 3 Preparing for Setup The box your chassis was shipped in should include two sets of rail assemblies two rail mounting brackets and the mounting screws you will need to install the system into the rack Please read this sec...

Page 38: ...han the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient tempera ture Tmra Reduced Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a rack so that...

Page 39: ...if you decide not to use a server rack Attach the inner rail extension to stabilize the chassis within the rack If you are not using a rack you do not have to install the inner rail extensions Installing the Inner Rails 1 Place the inner rack extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes Make sure the extension faces outward just like the pre...

Page 40: ...ck Figure 6 3 Assembling the Outer Rails Attach Outer Racks together Figure 6 4 Installing into a Rack Installing the Chassis into a Rack 1 Confirm that chassis includes the inner rails and rail extensions Also confirm that the outer rails are installed on the rack 2 Line chassis rails with the front of the rack rails 3 Slide the chassis rails into the rack rails keeping the pressure even on both ...

Page 41: ...r chassis should be positioned to balance the weight between front and back If a bezel is included on your server remove it 3 Attach the two front brackets to each side of the chassis then the two rear brackets positioned with just enough space to accommodate the width of the telco rack 4 Finish by sliding the chassis into the rack and tightening the brackets to the rack Note figures are for illus...

Page 42: ...Range 85 Vac Mini mum 100 240 Vac Nominal 264 Vac Max 85 Vac Minimum 100 240 Vac Nominal 264 Vac Max 11 3 Amp Rated AC Voltage 100 240 V 60 50 Hz 6 1 2 6 Amp 100 240 V 50 60 Hz 4 9 Amp 100 240V 50 60Hz 24 11 Amp 100 240V 47 63 Hz 100 240V 50 60Hz 10 4 Amp 5V standby 4 Amp 3 Amp 4 Amp 3 Amp 4 Amp DC Output 3 Amp at 5V standby 59 Amp at 12V 12V 42 Amps 59 Amp 58 Amp 62 Amp with PDB 57 Amp 5V 25 30 A...

Page 43: ... 1H PWS 333 1H20 Rated AC Volt age 100 240V 50 60Hz 8 4 Amp 100 240V 50 60Hz 8 5 4 Amp 100 240V 50 60Hz 8 5 4 Amp 100 240 V 50 60 Hz 4 5 Amp max 5V standby 3 Amp 3 Amp 3 Amp 3 Amp DC Output 12V 54 Amp 43 6 Amp 43 6 Amp 27 Amp 100 180 Vac 31 Amp 180 240 Vac 5V 25 Amp 25 Amp 25 Amp 18 Amp 3 3V 12 Amp 21 Amp 21 Amp 15 Amp 12V 0 5 Amp 0 6 Amp 0 6 Amp 0 5 Amp ...

Page 44: ... discharge Touch a grounded metal object before removing a component from the antistatic bag Handle the backplane by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the card and peripherals back into their antistatic bags when not in use B 2 General Safety Guidelines Always disconnect power cab...

Page 45: ... to utilize the most up to date technology available providing your system with reliable high quality performance This manual reflects BPN SAS 815TQ Revision 1 00 the most current release avail able at the time of publication Always refer to the Supermicro website at www su permicro com for the latest updates compatible parts and supported configurations 5V GND GND 12V 2 I C 5V 12V 5V 12V 1 2 3 0 ...

Page 46: ...deband Headers The sideband headers are designated JP51 For SES 2 to work properly you must connect an 8 pin sideband cable See the table to the right for pin definitions Sideband Headers Pin Definition Pin Definition 2 Backplane Addressing SB5 1 Controller ID SB6 4 Reset SB4 3 GND SB2 6 GND SB3 5 SDA SB1 8 Backplane ID SB7 7 SCL SB0 10 No Connec tion 9 No Connec tion 7 I2 C Connectors The I2 C Co...

Page 47: ...y the following conditions 1 Hard drive failure 2 Fan failure 3 System temperature over 45º Celsius Figure B 3 Front Connectors and Jumpers I2 C and SGPIO Modes and Jumper Settings This backplane can utilize I2 C or SGPIO I2 C is the default mode and can be used without making changes to your jumpers The following information details which jumpers must be configured to use SGPIO mode or restore yo...

Page 48: ...onnectors Rear Connector Connector Number SAS Drive Number SAS 0 J1 SAS SATA HDD 0 SAS 1 J2 SAS SATA HDD 1 SAS 2 J3 SAS SATA HDD 2 SAS 3 J4 SAS SATA HDD 3 D12 D5 SAS 0 D13 D6 SAS 1 SAS 2 SAS 3 D14 D7 D15 D8 Rear LED Indicators Rear Connector Hard Drive Activity Failure LED SAS 0 D12 D5 SAS 1 D13 D6 SAS 2 D14 D7 SAS 3 D15 D8 Figure B 5 Rear Connectors and LED Indicators ...

Page 49: ...prevent static discharge Touch a grounded metal object before removing a component from the antistatic bag Handle the backplane by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the card and peripherals back into their antistatic bags when not in use C 2 General Safety Guidelines Always discon...

Page 50: ...deband JP51 10 pin 7 I2C Connector JP44 4 pin 8 ACT_IN JP26 10 pin 9 SAS Port 0 J5 10 SAS Port 1 J6 11 SAS Port 2 J7 12 SAS Port 3 J8 1 3 1 4 1 1 1 5 1 6 1 8 1 7 1 2 1 9 1 11 1 10 Figure C 1 Rear Connectors 1 2 12 C 3 Version Information The BPN SAS3 815TQ backplane has been designed to utilize the most up to date technology available providing your system with reliable high quality performance Th...

Page 51: ...r and Upgrade Connector The JTAG connector designated JP47 and the upgrade connector designated JP46 are for diagnostic purposes These connectors should be used by a certified and experienced technician 5 MG9071 Chip The MG9071 is an enclosure management chip that supports the SES 2 controller and SES 2 protocols Main Power JP10 Pin Definition 1 12V 2 and 3 Ground 4 5V 1 Backplane Main Power Conne...

Page 52: ...tified with a square solder pad on the printed circuit board Note On two pin jumpers Closed means the jumper is on and Open means the jumper is off the pins Connector Pins Jumper Setting 3 2 1 3 2 1 Figure C 2 Rear Jumpers JP29 5V GND GND 12V 2 I C 5V 12V 5V 12V 1 2 3 0 ACT IN ACT0 ACT1 JTAG UPGRADE JP29 9071 RST JP18 BUZZER RESET ACT2 ACT3 SIDEBAND M9 M15 JP10 D3 JP18 J8 J7 J6 J5 JP29 JP44 R144 M...

Page 53: ...ailure LED red SAS 0 J1 D12 D5 SAS 1 J2 D13 D6 SAS 2 J3 D14 D7 SAS 3 J4 D15 D8 C 7 Rear LED Indicators Figure C 3 Rear LEDs 5V GND GND 12V 2 I C 5V 12V 5V 12V 1 2 3 0 ACT IN ACT0 ACT1 JTAG UPGRADE JP29 9071 RST JP18 BUZZER RESET ACT2 ACT3 SIDEBAND M9 M15 JP10 D3 JP18 J8 J7 J6 J5 JP29 JP44 R144 MH2 M46 J9 J10 JP26 JP47 JP46 JP42 JP33 JP34 JP40 JP51 REV 1 00 SAS815TQ S UPER R JP50 2 I C 5V 12V 1 2 0...

Page 54: ...reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demand...