Replacing the Power Supply
1. Your chassis includes a redundant power supply with two power modules.
You can leave the server running and remove only one power supply. If your
server has only one power supply, you must power-down the server and
unplug the power cord before replacing the power supply.
2. Push the release tab (on the back of the power supply) as illustrated.
3. Pull the power supply out using the handle provided.
4. Replace the failed power module with the same model.
5. Push the new power supply module into the power bay until it clicks into the
locked position.
6. Plug the AC power cord into the new power module.
Figure 5-17: Removing the Power Supply
Release Tab