6-4
SC842 Chassis Manual
6-4 Rack Mounting
Rack Mounting Overview
This section provides information on installing the SC842 chassis into an open rack.
There are a variety of rack units on the market, which may mean the assembly
procedure will differ slightly. You should also refer to the installation instructions that
came with the rack unit you are using.
Mounting the Chassis in an Open (Telco) Style Rack
To install the chassis into a Telco type rack, use one L-shaped bracket on either
side of the chassis (two total). First, determine how far follow the server will extend
out the front of the rack. Larger chassis should be positioned to balance the weight
between front and back. If a bezel is included on your chassis, remove it, then at-
tach the two front brackets to each side of the chassis. Finish by sliding the chassis
into the rack and tightening the brackets to the rack. Additional L-brackets may be
purchased separately if additional support is required.
Figure 6-1. Mounting in an Open Style Rack
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the floor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.
Warning: When initially installing the server to a rack, test that the rail locking tabs
engage to prevent the server from being overextended. Have a rack lift in place as
a precaution in case the test fails.
Note: figures are for illustrative purposes only. Always install servers into racks
from the bottom up.