4-13
Chapter 4: Chassis Setup and Maintenance
Figure 4-14. Secure the Serverboard onto the Chassis
Installing the Serverboard
1. Review your serverboard documentation. Become familiar with component
placement, requirements, precautions, and cable connections.
2. Open the chassis cover and remove the chassis from any power source.
3. Lay the serverboard on the standoffs.
4. Secure the serverboard to the standoffs using the rounded, Phillips head
mounting screws. Do not exceed eight inch-pounds of torque.
5. Secure the CPUs, heatsinks, and other components to the serverboard as
described in the serverboard documentation.
6. Connect the cables between the serverboard, backplane, chassis, front panel,
and power supply, as needed.
Mounting Procedure