8
SCE300 Chassis User's Manual
Rear Features
The chassis rear holds input/output ports.
Information LED
Status
Description
Continuously on and
red
An overheat condition has occurred.
(This may be caused by cable congestion.)
Blinking red (1Hz)
Fan failure, check for an inoperative fan.
Blinking red (0.25Hz)
Power failure, check for a non-operational power
supply.
Solid blue
Local UID has been activated. Use this function
to locate the server in a rack mount environment.
Blinking blue
Remote UID is on. Use this function to identify
the server from a remote location.
Figure 1-2. Rear Chassis View
Rear Chassis Features
Item
Features
Description
1
Power Input
The main power switch applies or removes primary power from the power supply
to the server but maintains standby power. To perform most maintenance tasks,
unplug the system to remove all power.
2
I/O ports
IPMI LAN, USB, LAN, SFP LAN, VGA
3
RJ45 window
Opening for an optional serial connector using an RJ45 jack
4
PCI window
Standard low-profile
5
K-slot for lock
Accepts a standard Kensington cable locking device (not included).
2
1
4
3
5