52
Chapter 4: Power Supplies and Fans
Chapter 4
Power
The SuperBlade enclosure integrates a power supply and a cooling fan into a single module.
The fan can operate independently from the power supply, so that if the power supply fails,
the fan continues to provide cooling for the system. The Chassis Management Module (CMM)
monitors the status of the power supplies and the power information for the enclosure.
Figure 4-1. Example Power and Fan Module, PWS-2K21A-BR
4.1 Module Description
An LED status indicator is located near the locking lever.
Status Indictor
Color
Description
Red
Power module failure
Amber
Possible module failure or the AC power cord unplugged
Green
Module operating normally
Power Cord
A plastic locking clip partially covering the socket was designed to prevent the power supply
module from being removed with the power cord still connected.
Only the recommended power cord or an equivalent 14 gauge cord should be used. Typical
C13/C14 cords are only 16 Gauge wiring and pose a fire hazard if substituted.