SuperBlade User’s Manual
5-4
4.
Move the locking clip away from the socket and reconnect the power cord.
Removing a Power Supply
First, make sure the power supply has been shut down. You can remove power from a
power unit via your system management software.
1.
Remove the power cord from the power supply unit.
2.
Release the locking clip to unlock the power supply module (see
Figure 5-3
).
Figure 5-3. Power Supply Module
3.
Pull out the handle and remove the unit: the two-piece handle locks into the closed
position. To release the handle, squeeze together the two metal plates of the handle
with your thumb and fingers and then pull out.
5-2
Power Supply Fans
Each power supply unit has four rear fans. These fans are not hot-swappable. If one
fails, the power supply will continue to operate but you should replace the power supply
unit at the earliest opportunity. If two or more fans fail, the power supply unit will shut
down and the LED on the back will turn amber.
Two-piece handle
Locking clip
AC input (C-20)
LED indicator
Summary of Contents for SuperBlade Series
Page 1: ...SuperBlade User s Manual Revison 1 0c...
Page 4: ...SuperBlade User s Manual iv Notes...
Page 8: ...SuperBlade User s Manual viii Notes...
Page 10: ...SuperBlade User s Manual x Notes...
Page 12: ...SuperBlade User s Manual xii Notes...
Page 22: ...SuperBlade User s Manual 1 10 Notes...
Page 30: ...SuperBlade User s Manual 3 6 Figure 3 4 Enclosure Installed into Rack...
Page 53: ...5 7 Chapter 5 Power Supply Modules Figure 5 6 Power Cable Tie and Clamp Assembly...
Page 54: ...SuperBlade User s Manual 5 8 Notes...
Page 58: ...SuperBlade User s Manual A 4 Notes...