Chapter 4: Chassis Setup and Maintenance
Server chassis that are 2U or higher require a power distributor. The power distribu-
tor provides failover and power supply redundancy. In the unlikely event you must
change the power distributor, do following:
Changing the Power Distributor
Power down the server and remove the AC power cord from the wall socket
1.
or power strip.
Remove all cable connections to the power supply from the motherboard,
2.
backplane, and other components. Also, remove both power supplies.
Locate the power distributor between the power supply and the fan row.
3.
Remove the three screws securing the power supply.
4.
Gently pull the power distributor from the chassis. Gently guide all the cables
5.
through the power distributor housing.
Slide the new power distributor module into the power distributor housing.
6.
Make that you slide the cables through the bottom of the housing.
Reconnect all the power cables, replace the power supply, and insert the AC
7.
power cord into the wall.
Figure 4-10: Changing the Power Distributor