10
Chapter 1: Introduction
1.2 System Features
The following views of the system display the main features. Refer to
specifications.
Front View
Figure 1-1. System Front View
Logical Storage Drive Numbers
Item
Description
0-11
Twelve 3.5-inch front drive bays (NVMe*/SAS*/SATA)
* NVMe or SAS support available with additional parts; see optional parts list
Drive Carrier Indicators
Each drive carrier has two LED indicators: an activity indicator and a status indicator. For RAID
configurations using a controller, the meaning of the status indicator is described in the table
below. For OS RAID or non-RAID configurations, some LED indications are not supported,
such as hot spare. For VROC configurations, refer to the
in this manual.
Drive Carrier LED Indicators
Color
Blinking Pattern
Behavior for Device
Activity
LED
Blue
Solid On
Idle SAS/NVMe drive installed
Blue
Blinking
I/O activity
Blue
Off
Idle SATA drive installed
Status
LED
Red
Solid On
Failure of drive with RSTe support
Red
Blinking at 1 Hz
Rebuild drive with RSTe support
Red
On for five seconds,
then off
Power on for drive with RSTe support
Red
Blinking at 4 Hz
Identify drive with RSTe support
Green
Solid Green LED
Safe to remove NVMe device
Amber
Blinking at 1Hz
Do not remove NVMe device
Control Panel
Service/Asset Tag
with
10
1
11
9
8
7
6
5
4
2
3
0