2-4
S
UPER
S
ERVER 6016T-6RFT+/6016T-6RF+ User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the 6016T-6RFT+/6016T-6RF+ into
a rack unit with the rack rails provided. If the system has already been mounted
into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack
units on the market, which may mean the assembly procedure will differ slightly.
You should also refer to the installation instructions that came with the rack unit
you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies in the rack mounting kit. Each
assembly consists of two sections: an inner fi xed chassis rail that secures directly
to the server chassis and an outer fi xed rack rail that secures directly to the rack
itself (see Figure 2-1). Two pairs of short brackets to be used on the front side of
the outer rails are also included.
Installing the Inner Rails
Both the left and right side inner rails have been pre-attached to the chassis. Pro-
ceed to the next step.
Figure 2-1. Identifying the Sections of the Rack Rails
(left side rail shown)
Inner Rail
Outer Rail
Locking Tab
Summary of Contents for 6016T-6RFT
Page 1: ...SUPERSERVER 6016T 6RFT SUPERSERVER 6016T 6RF SUPER USER S MANUAL 1 0 ...
Page 5: ...v Preface Notes ...
Page 21: ...Chapter 2 Server Installation 2 7 Figure 2 3 Installing the Server into a Rack ...
Page 23: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the System ...
Page 28: ...3 4 SUPERSERVER 6016T 6RFT 6016T 6RF User s Manual Notes ...
Page 71: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 5 Removing Replacing the Power Supply 1 2 ...
Page 72: ...6 10 SUPERSERVER 6016T 6RFT 6016T 6RF User s Manual Notes ...
Page 102: ...7 30 SUPERSERVER 6016T 6RFT 6016T 6RF User s Manual Notes ...
Page 104: ...A 2 SUPERSERVER 6016T 6RFT 6016T 6RF User s Manual Notes ...