SC835 Chassis Manual
5-14
The power supply is redundant and hot-swappable, meaning that the power supply
can be changed without powering down the system.
5-8 Power Supply
Replacing the Power Supply
Replacing the Power Supply
1. The server may continue running if only one power supply module is removed
at a time.
2. Unplug the power supply that will be replaced.
3. Push the release tab on the back of the power supply.
4. Pull the power supply out using the handle.
5. Replace the failed power module with another of the same model.
6. Push the new power supply module into the power bay until it clicks into the
locked position.
7. Plug the AC power cord back into the module and power up the server.
Summary of Contents for 835TQC-R1K03B
Page 1: ...SC835 Chassis Series SC835TQ R800B SC835TQ R920B SUPER USER S MANUAL 1 0c ...
Page 8: ...SC835 Chassis Manual viii Notes ...
Page 12: ...SC835 Chassis Manual 1 4 Notes ...
Page 32: ...2 20 SC835 Chassis Manual Notes ...
Page 54: ...SC835 Chassis Manual 5 16 Notes ...