3-21
Chapter 3: Troubleshooting
The Power Cycle function will shut down the managed system for a few seconds
and then power up the system. Graceful power control will send an event to the
System Event Log (next section). If no more memory space is left for the incoming
event, graceful power control will not function.
Chassis Power Control (Administrator and Operator only)
This function is used to forcibly control the power state of the managed system’s
chassis. When the BMC receives a chassis power control command, it will have
direct control over the power button or reset button of a system.
Reset
This is the same as pressing the Reset button on a managed system’s chassis to
reset the managed system.
Power Down
This is the same as pressing the Power button on a managed system’s chassis to
remove power from the managed system.
Power Up
This is the same as pressing the Power button on a managed system’s chassis to
turn on the power of the managed system.
Power Cycle
This function is a combination of the Power Down and Power Up functions.
The Power Cycle function will shutdown the managed system for a few seconds
and then power up the system.
BMC Cold Reset (Administrator only)
Clicking the Cold Reset button allows you to reset the BMC. After confirming to reset
the BMC, the session will break immediately. The user has to close this session
manually. This function is rarely used, only in events such as when a malfunction
is suspected.
Summary of Contents for AOC-1UIPMI-B
Page 1: ...USER S MANUAL Revision 1 0a AOC 1UIPMI B AOC IPMI20 E AOC LPIPMI LANG AOC 1UIPMI LANG SUPER ...
Page 13: ...2 2 AOC IPMI User s Manual 1 Figure 1 3 AOC 1UIPMI B Rear Layout 1 BMC Chip ...
Page 19: ...2 8 AOC IPMI User s Manual Notes ...
Page 27: ...3 8 AOC IMPI User s Manual Figure 3 Step 3 Figure 4 Step 4 ...
Page 28: ...3 9 Chapter 3 Troubleshooting Figure 5 Step 5 Figure 6 Step 6 ...
Page 45: ...3 26 AOC IMPI User s Manual Figure 3 6 3 9 BMC Setting Administrator only Figure 3 7 ...