6-8
AS2021M-UR+ User's Manual
Figure 6-4. Installing the Air Shroud
Installing the Air Shroud
Under most circumstances you will not need to remove the air shroud to perform
any service on the system. However, you may temporarily remove it if necessary
(the air shroud should always be in place when the system is operating).
1. To install, slide the air shroud's front lip into the groove located behind the row of
system fans. Make sure the air shroud cut-out aligns with the fan post.
2. Hook the bottom side fl aps of the air shroud to the rear fan chassis screw.
3. Pull the rear edges of the shroud outward and slide the heatsink fl aps under the
heatsink to further secure the air shroud.