5-2
AS2041M-32R+/2041M-T2R+ User's Manual
5-2 Processor and Heatsink Installation
Installing the Processors
(Install to the CPU#1 socket fi rst)
1. Begin by removing the cover plate
that protects the CPU. Lift the lever on
CPU socket #1 until it points straight up.
With the lever raised, lift open the silver
CPU retention plate.
2. Use your thumb and your index fi nger
to hold the CPU. Locate and align pin 1
of the CPU socket with pin 1 of the CPU.
Both are marked with a triangle.
Triangles
Installing the CPU Backplates
Four CPU backplates (BKT-0011L) have been preinstalled to the serverboard to
prevent the CPU area of the serverboard from bending and to provide a base for
attaching the heatsink retention modules.
Single, dual or quad-CPU confi gurations only are supported. For a single-CPU
confi guration, install to the CPU1 socket. For a dual-CPU confi guration, install to
the CPU1 and CPU2 sockets.
Exercise extreme caution when handling and installing the processor. Al-
ways connect the power cords last and always remove them before adding,
removing or changing any hardware components.
!
Summary of Contents for AS2041M-32R Plus
Page 1: ...AS2041M 32R AS2041M T2R USER S MANUAL 1 0 SUPER ...
Page 5: ...v Preface Notes ...
Page 16: ...1 6 AS2041M 32R 2041M T2R User s Manual Notes ...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the System ...
Page 30: ...3 4 AS2041M 32R 2041M T2R User s Manual Notes ...
Page 67: ...Chapter 6 Advanced Chassis Setup 6 5 Figure 6 3 Installing the Air Shroud ...
Page 73: ...Chapter 6 Advanced Chassis Setup 6 11 Figure 6 6 Removing Replacing the Power Supply ...
Page 74: ...6 12 AS2041M 32R 2041M T2R User s Manual Notes ...
Page 94: ...A 2 H8QM3 2 H8QMi 2 User s Manual Notes ...
Page 102: ...B 8 AS2041M 32R 2041M T2R User s Manual Notes ...
Page 106: ...C 4 AS2041M 32R 2041M T2R User s Manual Notes ...