SBA-7142G-T4 Blade Module User’s Manual
6-10
IPMI Configuration
The menu options in the IPMI C
ONFIGURATION
submenu and their descriptions are
shown in
Table 6-10
.
Table 6-10. IPMI Configuration Submenu
Menu Option
Description
IPMI Information
Display (Static)
This static display provides information for the Status of BMC and IPMI Firmware
Revision.
View BMC System
Event Log
This sub-menu allows you to view all events in the BMC Event Log. It will take a
maximum of 15 seconds to read all BMC SEL records.
SEL Entry
Number
Use the +/- keys to traverse the BMC Event Log.
Clear BMC System
Event Log
Use this option to clear all events in the BMC System Event Log.
Set LAN
Configuration
This is the input for the SET LAN Configuration command. See IPMI 1.5
Specification Table 19.1 for details.
NOTE:
Each question in this sub-menu may take a considerable amount of time
to complete.
IP Address
Use this sub-menu for IP Address configuration.
IP Address
Source
This setting allows you to specify either a
DHCP
or Static IP Address Soruce. If
you select Static for the IP Address Source, then the IP Address setting becomes
active.
IP Address
This setting allows you to set the IP Address for your LAN Configuration in
decimal format of XXX.XXX.XXX.XXX and with values less than 256. The
current IP Address is statically displayed below.
Subnet Mask
Use this sub-menu for Subnet Mask configuration.
Subnet Mask
This setting allows you to set the Subnet Mask for your LAN Configuration in
decimal format of XXX.XXX.XXX.XXX and with values less than 256. The
current Subnet Maks is statically displayed below.
Gateway
Address
Use this sub-menu for Gateway Address configuration.
Gateway
Address
This setting allows you to set the Gateway Address for your LAN Configuration in
decimal format of XXX.XXX.XXX.XXX and with values less than 256. The
current Gateway Address is statically displayed below.
MAC Address
Use this sub-menu for MAC Address configuration.
MAC Address
This setting allows you to set the IP Address for your LAN Configuration in hex
format of XX.XX.XX.XX.XX.XX. The current MAC Address is statically displayed
below.
Summary of Contents for SBA-7142G-T4
Page 1: ...SBA 7142G T4 Blade Module User s Manual Revison 1 0a ...
Page 4: ...SBA 7142G T4 Blade Module User s Manual iv Notes ...
Page 8: ...SBI 7226T T2 Blade Module User s Manual viii Notes ...
Page 10: ...SBI 7226T T2 Blade Module User s Manual x Notes ...
Page 12: ...SBI 7226T T2 Blade Module User s Manual xii Notes ...
Page 18: ...SBA 7142G T4 Blade Module User s Manual 1 6 Notes ...
Page 22: ...SBA 7142G T4 Blade Module User s Manual 2 4 Notes ...
Page 33: ...3 11 Chapter 3 Setup and Installation Figure 3 7 Installing a Hard Drive in a Carrier ...
Page 36: ...SBA 7142G T4 Blade Module User s Manual 3 14 Notes ...
Page 62: ...SBA 7142G T4 Blade Module User s Manual 6 14 Notes ...
Page 74: ...SBA 7142G T4 Blade Module User s Manual A 12 Notes ...