Chapter 4: Chassis Setup and Maintenance
4-13 Installing the Power Distributor
The power distributor provides failover and power supply redundancy and is
pre-installed in the chassis. In the rare event that you have to replace the power
distributor, follow the steps below.
Changing the Power Distributor
Power down the server and unplug the power cord from the power module.
1.
Remove all cable connections to the power supply from the motherboard,
2.
backplane, and other components. Also, remove both power supply modules.
Remove the screws securing the power distributor.
3.
Gently pull the power distributor from the chassis. Gently guide all the cables
4.
through the power distributor housing.
Slide the new power distributor module into the power distributor housing.
5.
Make that you slide the cables through the bottom of the housing.
Reconnect all the power cables, replace the power supply, and insert the plug
6.
into the wall.
Figure 4-19: Installing the Power Distributor