4-11
Chapter 4: Chassis Setup and Maintenance
The SC510T chassis comes equipped with three system fans for optimal cooling.
There is a single fan located behind the hard disk drives, and set of two fans located
in front of the motherboard. These fans circulate air through the chassis as a means
of lowering the chassis internal temperature.
4-7 Replacing System Fans
Figure 4-11: Identifying System Fans
Figure 4-10: Locating System Fans
Replacing System Fans
If necessary, open the chassis while the power is running to determine which
1.
fan has failed. (Never run the server for an extended period of time with the
chassis open.)
Turn off the power to the system and unplug the system from the outlet.
2.
Remove the failed fan's power cord from the serverboard.
3.
Remove the fan housing from the chassis by removing the two screws which
4.
attach the housing to the chassis. These screws are located in the mount-
ing thru holes on either side of the fan housing. (See figure 4-6). Set these
screws aside for later use.
Disconnect the fan wiring from the connectors and carefully lift the fan hous-
5.
ing out of the chassis.