6-9
Chapter 6 Rack Installation
Figure 6-5: Installing the Rack Rails
Installing the Chassis into a Rack
Installing the Chassis
1. Confirm that chassis includes the inner rails and the outer rails.
2. Align the inner chassis rails with the front of the outer rack rails.
3. Slide the inner rails into the outer rails, keeping the pressure even on both
sides (you may have to depress the locking tabs when inserting). When the
chassis has been pushed completely into the rack, you should hear the locking
tabs "click" into the locked position.
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the floor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.
Note: figures are for illustrative purposes only. Always install servers into racks
from the bottom up.