V 01-2017
www.superwind.com
45
Charge regulator is not
connected correctly
Check connection
referring to the wiring
diagram
Connect the charge regulator
correctly
Charge regulator
defective
For troubleshooting see
respective manual
Repair by authorized service station
11.5
Checking the open circuit voltage
A simple test to detect an internal defect of the generator is measuring the open circuit
voltage. Disconnect the cables from the generator and connect a voltmeter to the positive
and negative line. To avoid injury, dismantle the rotor blades beforehand. Now turn the
hub by hand. Count the revolutions within a certain period (e.g. 30 revs within 10 seconds
= 180 rpm). Watch the voltage. The voltage and the speed should correspond to the
following diagram:
Summary of Contents for 350 12V
Page 1: ...www superwind com Superwind 350 12V 24V Manual North Central and South America regions 01 2017...
Page 2: ...V 01 2017 www superwind com 1 Page intentionally left blank...
Page 52: ...V 01 2017 www superwind com 51 ATTACHMENT A Stop Switch Mounting Guidelines...
Page 53: ...V 01 2017 www superwind com 52 STOP SWITCH Mounting Guidelines Manual 01 2017...
Page 60: ...V 01 2017 www superwind com 59 ATTACHMENT B Superwind Charge Regulator 12V Marine...
Page 61: ...V 01 2017 www superwind com 60 Charge Regulator 12V Marine Instructions Manual 01 2017...
Page 70: ...V 01 2017 www superwind com 69 ATTACHMENT C Superwind Charge Regulator 24V Marine...
Page 71: ...V 01 2017 www superwind com 70 Charge Regulator 24V Marine Instructions Manual...