background image

Introduction

This is the 

Supra Wireless TRACcess Interface (WTI) 

Retrofit Installation Instructions

. Read these instructions 

before replacing the bezel interface with the wireless 

interface. If you do not mount the interface accurately, it 

will not function properly. Supra will not be responsible for 

replacing the interface if it is damaged or destroyed upon 

removal.

Installation supplies provided

• 

Drill template

• 

Exterior WTI interface plate

•  Two sets of four #8 flathead screws (two different 

screw lengths for the mounting plate)

• 

Four #8 × 5/16 in. pan-head screws and lock 

washers (for electronics enclosure)

•  Six #4 × 1/2 in. flathead screws
• 

Plastic weather cover assembly

CAUTION:

  The electronics in this package are 

electrostatic sensitive devices. Before you install the 

unit, discharge or use a grounding belt.

Installation tools required

• 

Drill

• 

Drill bits

• 

File

• 

Phillips screwdriver

• 

Level or punch

• 

Pen or pencil

 P/N 10103022P1 • November 2011

© 2011 UTC Fire & Security. All rights reserved.

Wireless TRACcess Interface (WTI) Retrofit

Installation Instructions

Figure 1.  Bezel interface and Wireless interface

Installation

To replace the bezel interface with the wireless interface 

(refer to Figure 2):

1.  Remove the screws from the electronics enclosure lid 

and then remove the lid.

2.  Disconnect the wiring plugged in to the electronics 

enclosure.  Make careful notes of the connection pin-

outs as the exterior WTI interface retrofit plate will be 

reconnected similarly. 

3.  Remove the four screws that secure the electronics 

enclosure to the interior plate and remove the 

electronics enclosure.

4.  Remove the four screws securing the old bezel 

interface plate to the interior plate.  Remove the old 

interface plate.

5. 

Feed the four-wire plug from the retrofit plate through 

the cabling hole in the door, and secure the interior 

mounting plate to the retrofit plate (Figure 2). Insert 

and tighten screws through interior mounting plate. For 

1-1/4 to 1-1/2 in. (32 to 38 mm) doors, use 3/4 in. (19 

mm) screws. For 1-1/2 to 2 in. (32 to 51 mm), use 1-1/4 

in. (38 mm) screws.

 

Note:

 If the screw does not fully secure the plates 

to the door when tightened, use a shorter screw. Do 

not overtighten the long screw.

6. 

Feed the four-wire plug from the retrofit plate, and the 

two-wire cable from the lockset through the cabling 

hole in the electronics enclosure. You will attach the 

wires after securing the enclosure.

7. 

Use the four #8 × 5/16 in. (16 mm) pan-head screws 

and lock washers to attach the electronics enclosure 

to the interior mounting plate.  Insert and tighten the 

screws and lock washers securely.

8.  Connect the two-wire cable and the four-wire plug 

as they were previously connected in the electronics 

enclosure.