background image

  FCC  Compliance Information 

18 

FCC  Compliance Information 

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. 

Operation is subject to the following two conditions: 

(1) This device may not cause harmful interference, and 

(2) This device must accept any interference received, including interference that may cause undesired operation. 

 

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the 

FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. 

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not 

occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the 

following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

Modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment under FCC 

rules. 

 

 

 

 

Summary of Contents for bioentry PLUS

Page 1: ...BioEntry Plus INSTALLATION GUIDE EN 101 00 BEP V2 12A Version 2 12 English...

Page 2: ...Network 10 TCP IP 10 Connecting to an Door button Door sensor 11 Digital input connection Door button Door sensor 11 Digital input connection Alarm Emergency switch 11 Connecting to a Relay 12 Fail Sa...

Page 3: ...c shock or injury If the product is damaged due to a user s unauthorized installation or dismantling of the product a service fee will be charged for repair Operating Instructions Be careful not to sp...

Page 4: ...nts NOTE Components may vary according to the installation environment BioEntry Plus Wall Bracket Diode Fixing Screw x 2 Bracket Fixing Screw Star Shaped 3 pin 4 pin 5 pin 7 pin cables 1 pc for each Q...

Page 5: ...ery 2 seconds Failure to reset Contact the manufacturer Yellow flashes every 2 seconds Waiting for an input Fingerprint reader Reads fingerprints placed on it for entering and exiting 5 pin cable conn...

Page 6: ...ame Color RJ45 Pin number 1 ENET TXP Yellow 6 2 ENET TXN Green 3 3 ENET RXP Red 2 4 ENET RXN Black 1 Wiegand input output switchable Pin Name Color 1 WG D0 Green 2 WG D1 White 3 WG GND Black Digital i...

Page 7: ...rint Registering a finger is the most important procedure because this device uses the registered fingerprint to compare it with a fingerprint that the device tries to read Please ensure the following...

Page 8: ...lled onto a concrete wall make a hole with a drill and then insert a PVC anchor into the hole before screwing the mounting screw 2 Attach BioEntry Plus onto the mounted bracket 3 Assemble BioEntry Plu...

Page 9: ...by other devices the power adapter should provide a current more than the sum of the power consumption from this device 1 500 mA and other devices Use a separate power supply for Secure I O 2 electri...

Page 10: ...can be used to connect to a hub LAN connection connecting directly to a PC BioEntry Plus can be connected directly to a PC by using a normal straight type CAT 5 cable because it supports an automatic...

Page 11: ...r button Door sensor Digital input connection Alarm Emergency switch Switch 1 Switch 0 BioEntry Plus 1 TTL IN0 Yellow 2 TTL GND Black 3 TTL IN1 Green 4 TTL GND Black 4 3 2 1 Door sensor Door button Bi...

Page 12: ...r BioEntry Plus from the door lock device Fail Secure Lock To use fail secure lock connect N O terminal as shown below Normally there is no current flowing through the relay and the door is opened whe...

Page 13: ...ntry Plus PC Door button Door sensor Door Lock Input 0 Relay Input 1 1 TTL IN0 Yellow 2 TTL GND Black 3 TTL IN1 Green 4 TTL GND Black 5 RLY NC Orange 6 RLY COM Blue 2 1 5 6 4 3 BioEntry Plus Automatic...

Page 14: ...ting will deterior ate because it reduces the signal level If the termination resistor of BioEntry Plus is required set the 1 DIP switch to ON Up to 32 devices can be connected via daisy chain 1 maste...

Page 15: ...e device with default values TCP IP address DHCP address assignment If DHCP address assignment is failed 169 254 0 1 will be set Server mode Disabled RS 485 Default 115200 bps 4 Change the TCP IP addr...

Page 16: ...wo templates per finger Max Template 1 N 10 000 Two templates per finger Max Text Log 50 000 Interface TCP IP Yes RS 485 1ch Host or Slave Selectable Wiegand 1ch In or Out Selectable TTL Input 2 Input...

Page 17: ...Product Specifications 17 Dimensions Unit mm Front view Side view Bracket...

Page 18: ...if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular inst...

Page 19: ...ve employees subsidiaries branches partners and distributors of Suprema are exempt from liability even when it is claimed that there is a significant fault in the design or production process and also...

Page 20: ...nquiry sales supremainc com 2018 Suprema Inc Suprema and identifying product names and numbers herein are registered trade marks of Suprema Inc All non Suprema brands and product names are trademarks...

Reviews: