3. TECHNICAL SPECIFICATION
SPECIFICATIONS
MODEL
9 KW
13 KW
17 KW
20 KW
Mode Type
Heat & Cool
Discharge
Side
Fan Quantity
1
Performance at Air 27°C, Water 26°C, Humidity 80%
Heat Capacity
kW
9.5
13
16.5
20
COP
6.4-13.5
5.8-13.1
6.2-13.6
6.5-13.8
Performance at Air 15°C, Water 26°C, Humidity 70%
Heat Capacity
kW
7.1
9.2
12.6
14.5
COP
4.7-7.4
4.5-7.1
4.7-7.4
4.8-7.5
General
Rated input power at air 15°C
kW
0.20-1.51
0.27-2.04
0.32-2.68
0.35-3.02
Rated input current at air 15°C
Amps
8.4
10.9
16.6
17.5
Circuit Breaker
Amps
15
15
20
25
Power Supply
240v / 50Hz / 1PH
Pool Volume - Cold Climate
Litres
≤20,000
≤30,000
≤40,000
≤50,000
Pool Volume - Warm Climate
Litres
≤30,000
≤40,000
≤50,000
≤60,000
Advised Flow Rate
L/min
53
66
86
100
Inlet / Outlet
mm
50
Compressor
Twin-rotary Mitsubishi DC Inverter
Heat Exchanger
Spiral titanium tube in PVC
Casing
Black ABS
Noise Level (1m)
dBA
39-51
42-53
43-54
44-55
Weight / Dimensions
Net Weight
kg
45
45
60
70
Net Dimensions L x W x H
mm
1002 x 403 x 602
1002 x 403 x 602
1048 x 435 x 767
1161 x 470 x 862
The sizing of heat pumps are based on pool volume for seasonal swimming with the use of a Heatseeker Pool Cover.
1.
The values indicated are valid under ideal conditions: Pool covered with an isothermal cover.
2.
Related parameters are subject to adjustment periodically for technical improvement without
further notice. For details please refer to nameplate.
Heatseeker NovaS Heat Pump
Installation & User Manual
11
Summary of Contents for Heatseeker NovaS
Page 37: ...10 9 Device Management Heatseeker NovaS Heat Pump Installation User Manual 35...
Page 38: ...Heatseeker NovaS Heat Pump Installation User Manual 36...
Page 42: ...NOTES Heatseeker NovaS Heat Pump Installation User Manual 40...
Page 43: ...Heatseeker NovaS Heat Pump Installation User Manual 41...