8.4 INSTALLATION INSTRUCTIONS
8.4.1 Mounting
Find a suitable location to mount the NovaSwitch box. Ideally as with all pool equipment it should
be installed out of direct weather and no closer than 3m from the water’s edge and a minimum of
600mm above ground. Lift up the two mounting tabs and use two appropriate screws to mount the
NovaSwitch box to the wall, keeping in mind that the power cable is 1.8m long and should be plugged
directly into a general power outlet, not into an extension lead.
8.4.2 Pump
The circulation pump plugs into the 240V outlet beneath the NovaSwitch.
8.4.3 Heating Priority
Connect the heat pump control cable from the NovaSwitch to the heat pump, refer to the heat
pump manufacturer’s instructions and the below diagram for the appropriate connection and note
that damage caused by incorrect connections will void warranties.
ATTENTION
Must be installed by an electrician.
Heatseeker NovaS Heat Pump