9.4 INSTALLATION INSTRUCTIONS
9.4.1 Mounting
Find a suitable location to mount the NovaLink box. Ideally, as with all pool equipment, it should be
installed out of direct weather and no closer than 3m from the water’s edge and a minimum 600mm
above ground. Fix the mounting bracket to a solid structure and slide the NovaLink on, keeping in mind
that the power cable is 1.8m long and should be plugged directly into a general power outlet, not into
an extension lead.
9.4.2 Pump
The filtration pump plugs into the 240V outlet beneath the NovaLink. (Marked pump on the
controller face).
9.4.3 Heat Demand
Connect the Heat Control cable from the controller to the following points for the appropriate heat
pump. The relay must be enclosed within the heater. Damage caused by incorrect connections will
void warranties.
Connections for compatible Nova heat pumps are:
ATTENTION
Must be installed by an electrician.
Heatseeker NovaS Heat Pump
Installation & User Manual
29