24
Figure 3-39: Front and Side Chase for Clean Face Dual Louver Configuration
Figure 3-40: Front Chase for Traditional Surround Option
Figure 3-41: Front Chase for Clean face Linear Louver
Configuration
3.7 Chase Installation
A portion of the front of the chase must be constructed out non-combustible material. Refer to Figure 3-39, 3-
40, and 3-41 for dimensions. Note the chase must be properly fastened onto the framing structure.
WARNING: Do not nail or screw the chase onto the fireplace.
For the clean face surround option, two intake openings must be constructed onto the chase, as well as two
outtake openings or one if installing the linear single louver front (Section 3.5). Refer to Figures 3-39 and 3-41
for minimum clearances.
Summary of Contents for 38SF