30 

 

Figure 4-6: Installation of Fresh Air Kit 

4.2  Fresh Air Kit 

Sufficient  air  exchange  is  necessary  for  the  fireplace  to 
operate  properly  and to maintain  a good  combustion. In 
an  airtight  household,  the  fireplace  may  not  function  as 
designed  due  to  a  lack  of  air;  it  is  therefore 
recommended  to  install  the  fresh  air  kit  in  such  cases. 
The  fresh  air  system  is  an  optional  kit  intended  to  bring 
combustion air into the fireplace from an exterior source. 
Note  that  a  minimum  distance  of  seven  inches  is 
required  between  the  side  of  the  unit  connecting  to  the 
fresh  air  kit  and  the  framing  to  allow  significant  space 
(refer to Figure 3-4). 

Note that the Elegance 42 is designed to use a minimum 
amount of air during operation. Using an air exchanger or 
simply opening a nearby window/door during the ignition 
of the unit will achieve a similar result as the fresh air kit. 
When the fireplace is idle, there is no air escaping from the house through chimney. 

Consult a local authority 

having jurisdiction (such as the fire department, the municipal building department, the fire prevention 
bureau) to determine if it is mandatory to install a fresh air kit in your area. 

General Notes:  

The outside air kit should be installed according to the following guidelines:  

  The air duct must be insulated, wrapped with a vapor barrier, and have an inner diameter of 4 inches.  

  The length of the air duct should not exceed 25 feet. 

  The duct should not be elevated more than 10 feet from the base of the unit. 

  Fresh air must come from the outside and not from another room or the attic.  

  The outside register must be away from automobile exhaust fumes, gas meters, or other vents.  

  Avoid installing the air register where it will likely be covered by snow or exposed to strong winds.  

  The air register can be installed above or below the level of the fireplace. 

  Use the SUPREME FIREPLACES INC. Fresh Air Adapter (ADP4) provided with the unit. 

  Use the SUPREME FIREPLACES INC. Fresh Air Kit (UPEA4). 

Installation:  

1.  Cut  4  ½

”  diameter  hole  on  the 

exterior wall of an ideal location.  

2.  Install the air register on the exterior 

wall. 

3.  Insert  the  fresh  air  adapter  (ADP4) 

into  the  fireplace  from  the  exterior 
casing.  Make  sure  that  the  adapter 
is 

properly 

inserted 

into 

the 

combustion  air  box  on  top  of  the 
firebox. 

4.  Secure  the  fresh  air  adapter  to  the 

side  of  the  fireplace  using  two 
screws. 

5.  Install the air duct and secure it with 

worm gear clamps. 

Figure 4-5: ADP4 Installation in Fireplace 

Summary of Contents for 38SF

Page 1: ...This product is proudly developed and manufactured in North America by SUPREME FIREPLACES INC 3594 Jarry East Montreal QC H1Z 2G4 T 877 593 4722 F 514 593 4424 www supremem com Revised June 2022 IMPO...

Page 2: ...11 Soapstone Interior 7 2 12 Blower Kit 7 2 13 Optional Hot Air Kit 7 2 14 Optional Fresh Air Kit 7 INSTALLATION INSTRUCTIONS 8 3 1 Location 8 3 2 Chimney Installation 9 3 2 1 General Rules and Guide...

Page 3: ...Operating the Combustion Air Control 31 5 4 Starting a High Efficiency Fire 32 5 5 Adding a New Load of Wood 33 5 6 Blower Kit Operation 33 TROUBLESHOOTING 34 6 1 Backdraft Smoking 34 6 2 Over Firing...

Page 4: ...materials are respected Contact with the unit during operation may cause severe harm Install a safety screen to keep children and pets away CAUTION Do not connect this unit to a chimney flue serving a...

Page 5: ...2 Figure 2 1 Elegance 42 Traditional Rectangular Dimensions Figure 2 2 Elegance 42 Traditional Arched Dimensions GENERAL INFORMATION 2 1 Overall Dimensions 2 1 1 Traditional Dimensions...

Page 6: ...3 Figure 2 3 Elegance 42 Clean Face Rectangular Dimensions Figure 2 4 Elegance 42 Clean Face Arched Dimensions 2 1 2 Clean Face Dimensions...

Page 7: ...00 ft2 93 to 232 m2 Average Particulate Emissions Rate2 1 85 g hr Average CO Emissions Rate3 2 09 g min EPA Protocol Method 28R ASTM2780 10 and ASTM2515 11 Efficiency Crib Wood HHV4 67 83 LHV5 72 9 He...

Page 8: ...a minimum burn rate is set WARNING Never manipulate the Combustion Air Control with bare hands as it gets hot when the Elegance 42 is in operation Use the Cold Hand Key see Section 2 4 to adjust the...

Page 9: ...e hearth The Ash Lip can be installed with the door open or closed It is safe to operate the unit without the Ash Lip NOTE The door of the Elegance 42 must remain closed at all times during operation...

Page 10: ...mmended when the fireplace is installed in an area below the maximum heating space A total of three kits can be installed onto one unit with a maximum distance of 25 feet each Note that a 5 inch insul...

Page 11: ...d 3 8 The clearances to combustible materials The passage of the chimney If possible select a location for the fireplace that will minimize the number of offsets in the chimney course Offsets will red...

Page 12: ...minimum length of 12 inches of straight chimney is required from the top of the unit before having an offset 5 Only chimneys approved under the UL 103 ULC S629 standards can be installed onto the uni...

Page 13: ...um clearance to combustibles 2 For an installation with the chimney running through the ceiling install the SUPREME Radiation Shield Offset below the chimney opening prior to installing the radiation...

Page 14: ...ney length s necessary for the offset 3 Once the desired offset length has been achieved install the second elbow to redirect the venting to the vertical position 4 Cut an opening in the floor ceiling...

Page 15: ...e Elegance 42 running through a masonry chimney 1 Install the anchor plate onto the unit 2 Position the fireplace to the recommended location 3 Install the initial prefabricated chimney lengths and el...

Page 16: ...t be constructed with nominal 2 x 3 or 2 x 4 metal studs and the remainder can be constructed with nominal 2 x 3 or 2 x 4 lumber Refer to Figure 3 10 for an example of a framing design and Figure 3 11...

Page 17: ...place it on a soft surface such as a carpet or cardboard to avoid any scratches or damages 2 Align the lower support bracket Item 6 to the intake opening and fasten it in place Figure 3 13 3 Bend the...

Page 18: ...3 19 within the door holder and secure it in place with 4 black screws one on each corner Make sure that the handles of the Combustion Air Control pass through the slots of the surround 5 Reinstall th...

Page 19: ...3 17 Clean Face Surround Installation Table 3 4 UWA620 Components CLEAN FACE RECTANGULAR ITEM DESCRIPTION QTY 4 Clean Face Rectangular Surround 1 7 Clean Face Upper Cover 1 8 Clean Face Lower Cover 1...

Page 20: ...etermine the two locations of the air outtakes on the chase and cut a rectangular opening 10 5 W X 9 5 H Note that a minimum distance of 64 is required from the floor and a minimum of 6 is required fr...

Page 21: ...gravity ducts must not be connected to a central heating system A clearance must be maintained between the gravity ducts and the chimney The intake swivel covers at the bottom sides must remain open...

Page 22: ...The base of the louver must be at least 64 from the base of the unit Refer to Figure 3 11 in Section 3 3 for framing requirements of single linear front louver installations WARNINGS A minimum clearan...

Page 23: ...linear duct louver adapter item SL1110 of Figure 3 25 and Table 3 7 onto the framing of the single linear front louver Figure 3 26 The brackets of the SL1110 SL1153 of Figure 3 25 are adjustable to a...

Page 24: ...distance L and cut the two CAC8 ducts Figure 3 25 and Table 3 7 to that length 5 Insert a worm gear clamp on each end of the ducts Figure 3 30 6 Install the 90 elbows on one end of the ducts and secur...

Page 25: ...ase finishing material of 30 75 W X 4 5 H centered with the outlet Figure 3 35 11 Determine the two locations of the air intakes on the chase and cut the rectangular openings of 15 25 W X 4 5 H Figure...

Page 26: ...tar bricks or ceramic tiles Note that unidentified materials may be combustible verify product specifications prior to installation The hearth extension must extend a minimum of 18 from the front of t...

Page 27: ...t be constructed out non combustible material Refer to Figure 3 39 3 40 and 3 41 for dimensions Note the chase must be properly fastened onto the framing structure WARNING Do not nail or screw the cha...

Page 28: ...Base of unit The depth of the mantle is measured from the face of the fireplace door When the non combustible wall is recessed the depth of the mantle can be increased by the amount of the recess see...

Page 29: ...onto the stainless steel bracket The following are instructions on installing the blower kit into the Elegance 42 refer to Figure 3 45 for the electrical diagram 1 Using two screws install the therm o...

Page 30: ...27 Figure 3 46 Access to Blowers Figure 3 47 Blower and its Fixture Figure 3 44 Access to Blowers Figure 3 45 Electrical Diagram...

Page 31: ...the hot air kit may result in overheating will void the warranty and can be hazardous WARNINGS Do not install the blower within the casing of the fireplace The minimum wall opening to run the duct is...

Page 32: ...sure to remove any pieces of insulation that has fallen into the unit 3 Install the fireplace duct connector FDC 5 on the opening using four screws 4 In the room where the heat will be distributed cut...

Page 33: ...o install a fresh air kit in your area General Notes The outside air kit should be installed according to the following guidelines The air duct must be insulated wrapped with a vapor barrier and have...

Page 34: ...these materials may result in release of toxic fumes or render the heater ineffective and cause smoke Do not over fire the Elegance 42 fireplace Over firing will damage the fireplace is hazardous and...

Page 35: ...r this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual 5 4 Starting a High Efficiency Fire The Elegance 42 has patented technologies a...

Page 36: ...at the center of the firebox d Activate the Activator by pushing it in e Once the embers begin to glow red add the new load of wood in the firebox f Keep the door of the Elegance 42 slightly unlatched...

Page 37: ...the firebox Backdraft is most commonly caused by fans around the house such as in the kitchen and bathrooms simultaneously in operation insufficient length of the chimney less than 15 feet or a block...

Page 38: ...flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney connector and chimney burning wood or coal s...

Page 39: ...out of the firebox d Slide the back wall soapstone panel by tilting the bottom and swivelling them out of the top retainer e Replace the damaged soapstone panel if it was removed in step d and positi...

Page 40: ...from the door and the surroundings c Remove the door from the firebox and place it face down on a soft surface NOTE Rotate the handle to permit proper placing d Using a wedging tool or flat head scre...

Page 41: ...erature paint in aerosol spray can format by Stove Bright in Metallic Black 6309 Contact your local hearth shop for further information on purchasing this paint NOTE Apply the paint in a well ventilat...

Page 42: ...ertified UL CSA WALL_RHEO In Wall Variable Speed Control 2 5 Amps 115VAC 50 60Hz certified UL ULC PA5000 01 Combustion Air Control CM0020 Cold Hand Key CM0301 01 Removable Ashlip 38SF1175 Soapstone Sl...

Page 43: ...40 CERTIFICATION LABEL...

Page 44: ...series circulating chamber of fireplace insert series bimetallic strip of combustion air control removable ash lip surround structure cold hand key wall intake and outtake grilles of gravity kit 10 y...

Page 45: ...ion alterations or substitutions of components of the fireplace abrasives chemical cleaners and negligence are not covered by this warranty Burning anything other than natural wood will damage your fi...

Reviews: