background image

 

Summary of Contents for BioStaion T2

Page 1: ......

Page 2: ...n check Embedded Web Server The embedded web server BioStar Lite allows administrators to manage users and devices through a web browser in any PC without S W and database installation Fast matching s...

Page 3: ...ly heavy pressure to the touch screen Keep the terminal away from any heating devices or heat sources Do not disassemble repair or reconstruct the terminal without any direction of Suprema Otherwise y...

Page 4: ...0 Dimensions 11 Menu Screen 12 Standby Screen 13 Authentication Mode 14 How to place a finger 15 2 Installation 17 Installation 18 Connector Cable Specifications 19 232 CABLE 3 pin Connector 19 SWITCH...

Page 5: ...Connector 36 Wiegand Output 5 pin Connector 36 System Configuration 37 Standalone 37 Secured 37 Network Configuration 38 3 User Menu 39 Access Authentication 40 Fingerprint Authentication 40 Fingerpr...

Page 6: ...tup 64 TCP IP Setup 64 Server Setup 65 Serial Communication 65 USB 66 USB Memory 66 Wireless LAN 67 Authentication Mode 68 Finger Auth Mode 68 Card Auth Mode 68 ID Auth Mode 69 Operation 69 T A Mode 7...

Page 7: ...BioStation T2 User Guide http www supremainc com 6 1 Before Getting Started...

Page 8: ...ted 7 Please check the package and ensure that all of the components are prepared Components Basic Components Software CD 1 copy BioStation T2 Body Wall Bracket Screws and PVC Anchors 4 EA each Mini U...

Page 9: ...rprint scanner for enrollment on PC Access Point For Wireless Model only RF Cards Analog Video Phone Power Adapter Note The product shown above is just an image to illustrate the product Depending on...

Page 10: ...Used for still image logs and video interphone 4 Card reader Reads a RF card 5 Fingerprint Sensor LED Displays the status of the fingerprint sensor 1 ON Waiting for fingerprint input 2 Blinking Reques...

Page 11: ...LAN device is mounted before released from the factory 2 RJ45 Socket Connects Ethernet cable 3 4 3 pin Connector Connects RELAY 0 1 5 6 4 pin Connector Connects RS485 0 1 7 8 Termination Switch RS485...

Page 12: ...BioStation T2 User Guide 1 Before Getting Started 11 Dimensions 155mm W x 155mm H x 40mm D Rear Side Bracket 155 mm 155 mm 40 mm 135 mm 134 2 mm 109 mm...

Page 13: ...tional T A events 4 Menu Enters the administrator menu 5 T A Key Display Describes operations of F1 F4 CALL keys The buttons work like F1 F4 CALL keys 1 Displays whether or not to use face detection o...

Page 14: ...r the status bar Setting the Background Screen Notice Slide PDF Other Standby Screens Locked You can lock the terminal using the tampers position or a specific input port To unlock the terminal admini...

Page 15: ...rd reader and then input the fingerprint Card Fnger Pin For authentication place the registered card onto the card reader and then input the fingerprint or type the password Card Finger Pin For authen...

Page 16: ...ually opposite to lower part of a nail It is recommended to place a finger as the lower part of a nail is located at the center of a sensor 3 If a finger is placed as in the right picture only a small...

Page 17: ...finger correctly with care 2 In case of low acceptance ratio the following actions are recommended Delete enrolled fingerprints and re enroll the fingers Enroll the same finger additionally Try with...

Page 18: ...BioStation T2 User Guide http www supremainc com 17 2 Installation...

Page 19: ...cation determine the place where the product should be installed We recommend you to install the product at the height of 130 cm 140 cm from the floor and the minimum distance between the product and...

Page 20: ...Pin Name Cable Type Color 1 232RX AWG26 GREEN 2 232TX YELLOW 3 GND BLACK SWITCH CABLE 8 pin Connector Pin Name Cable Type Color 1 SWITCH INPUT0 AWG26 YELLOW 2 SWITCH INPUT1 GREEN 3 SWITCH GND BLACK 4...

Page 21: ...e Color 1 RELAY NORMAL OPEN AWG24 WHITE 2 RELAY COMMON BLUE 3 RELAY NORMAL CLOSE ORANGE WIEGAND CABLE 5 pin Connector Pin Name Cable Type Color 1 DATA0 AWG26 GREEN 2 DATA1 WHITE 3 GND BLACK 4 SHIELD G...

Page 22: ...in Name Cable Type Color 1 VOICE SIGNAL AWG26 RED 2 GND BLUE 3 POWER YELLOW 4 VIDEO SIGNAL WHITE 5 DOOR OPEN SIGNAL ORANGE 6 GND BLACK 7 SHIELD GND GRAY RS485 CABLE 4 pin Connector Pin Name Cable Type...

Page 23: ...tor Note Recommended Power Specification You should use a 12V adapter which is covered by IEC EN 60950 1 providing voltage of 12V 10 and a current of 1500mA or above It is recommended that the power o...

Page 24: ...BioStation T2 User Guide 2 Installation 23 USB Cable Connection...

Page 25: ...BioStation T2 User Guide 2 Installation 24 Ethernet Connection Ethernet Cable Connect the RJ45 socket on the rear of the product to the hub with an Ethernet LAN cable...

Page 26: ...BioStation T2 User Guide 2 Installation 25 Ethernet Connection Direct connection to PC...

Page 27: ...tion 26 PoE hub connection PoE Power over Ethernet is an Ethernet connection of which power is provided by IEEE802 3af standard compliant PSE Power sourcing Equipment Note If you use PoE the length of...

Page 28: ...s LAN device is mounted before released from the factory Note The performance of a wireless LAN depends on the type of the AP access point and the environment Some wireless APs will not be fully compa...

Page 29: ...may not be successful The USB memories listed below are fully compatible with the BioStation T2 IMATION Flash Drive Nano 4GB LG Electronics X TICK M4 4GB LG Electronics X TICK MOBY J1 2GB PQI Travelin...

Page 30: ...Dip Switch for normal signal transmission On the other hand if the cable is too short the resistance may interrupt signal transmission Therefore by considering the length of the cable and the signal s...

Page 31: ...5 Connection to Secure I O or Other Terminals 4 pin Connector Note One RS485 network can be connected to 8 terminals in maximum including a Host Caution If you do not connect GND the RS485 chip may be...

Page 32: ...BioStation T2 User Guide 2 Installation 31 RS232 Connection...

Page 33: ...BioStation T2 User Guide 2 Installation 32 Videophone Connection Note The only following videophone models are compatible with BioStation T2 COMMAX CAV 35N COMMAX CAV 50H COMMAX CAV 50P...

Page 34: ...3 pin Connector Note Normally Open N O When no control signal is received the electricity does not flow When control signals are received the electricity continues flowing Normally Close N C When no...

Page 35: ...BioStation T2 User Guide 2 Installation 34 Relay Connection Automatic Door 3 pin Connector...

Page 36: ...BioStation T2 User Guide 2 Installation 35 TTL Switch Input Connection 8 pin Connector...

Page 37: ...tion T2 User Guide 2 Installation 36 Wiegand Input 5 pin Connector Wiegand Output 5 pin Connector Note There is only one Wiegand port Select either of Wiegand Output and Wiegand Input using BioStar so...

Page 38: ...er Guide 2 Installation 37 System Configuration Standalone A terminal works both of door control and authentication functions Secured A terminal works as authentication function Secure I O works as a...

Page 39: ...BioStation T2 User Guide 2 Installation 38 Network Configuration LAN and RS485 allow integrated management...

Page 40: ...BioStation T2 User Guide http www supremainc com 39 3 User Menu...

Page 41: ...ation success screen is displayed Note The authentication success screen is then displayed only when the card authentication has succeeded If the user s picture has been registered he user s picture i...

Page 42: ...ways or the desired time schedule How to Authenticate 1 Press the desired T A Key F1 F4 2 Place a finger on the sensor 3 A PIN number input window appears Enter the password PIN number and then press...

Page 43: ...IN number input window appears Enter the password Pin number and then press OK 3 An authentication success screen is displayed Card Fingerprint Authentication How to Set 1 Menu Mode Card Auth Mode Car...

Page 44: ...r type the password 3 An authentication success screen is displayed Card Fingerprint Password Authentication How to Set 1 Menu Mode Card Auth Mode Card Finger Pin 2 Select either of Always or the desi...

Page 45: ...IN number input window appears Enter the password PIN number and then press OK 4 An authentication success screen is displayed ID Fingerprint Authentication How to Set 1 Menu Mode ID Auth Mode ID Fing...

Page 46: ...ssword or place the finger on the scanner 4 An authentication success screen is displayed ID Fingerprint Password Authentication How to Set 1 Menu Mode ID Auth Mode ID Finger Pin 2 Select either of Al...

Page 47: ...riod in BioStar To change the current T A event to another T A event press the T A key to select the desired T A event Manual Fix by key input If the T A mode is set to Manual Fix mode you can select...

Page 48: ...reen or the F1 to F4 keys In Arrive at work Out Leave after work In Duty Return during work Out Duty Leave temporarily during work Additional T A Event You can select the additional T A events predefi...

Page 49: ...tication is limited by authentication interval limit Exceeded count I Displayed when the number of authentications exceeds the specified authentication count Access is not granted I Displayed when the...

Page 50: ...BioStation T2 User Guide http www supremainc com 49 4 Admin Menu...

Page 51: ...nal settings 1 Select Menu User Enroll User 2 Enter the user ID and at least one of card information password and fingerprints 3 Check the Admin Level checkbox and then press Save button Note The admi...

Page 52: ...ny authentication procedures The general user not the administrator enters into his her entrance T A log check screen See p 47 1 On the main screen press Menu 2 The Enter Admin menu screen is displaye...

Page 53: ...BioStation T2 User Guide 4 Admin Menu 52 Configuration of Admin Menu...

Page 54: ...BioStation T2 User Guide 4 Admin Menu 53...

Page 55: ...BioStation T2 User Guide 4 Admin Menu 54 User Enrollment Process...

Page 56: ...he device when a user is registered to the device To use the CSN card select Mode Operation Card Mode and select Use CSN The EM model supports CSN card authentication mode only 1 After entering into t...

Page 57: ...e Enter the name and then press OK You can use Korean characters alphabets numbers and special characters Fingerprint Select Fingerprint and then the fingerprint registration procedure starts You can...

Page 58: ...not be registered Administrator If this checkbox is checked the user is registered as an administrator If not the user is registered as a general user Duress Finger Duress Finger offers users a way o...

Page 59: ...tion mode for the terminal The individual authentication mode works for the corresponding authentication means only Note To use the individual authentication mode select Menu Mode Operation and check...

Page 60: ...t of new user registration 3 The success screen is displayed To delete a specific user follow the procedure below 1 In the user list check the checkbox of the user to be deleted 2 Click the Delete ico...

Page 61: ...K The user whose ID matches to the entered ID is searched A name search window appears Enter the name and then press OK It is not necessary to enter all characters of the name When you enter some star...

Page 62: ...er up to 200 000 users or 400 000 fingerprint templates and 5 000 user face images on the device Deleting All Users You can delete all users registered in the terminal 1 Select Menu User Delete All Us...

Page 63: ...ion Card Mode and select Use Template Card 1 Select Menu User Issue Card 2 A registration window appears Enter the user information 3 Enter the User ID Name Fingerprint and Password 4 Set the Administ...

Page 64: ...nu 63 Formatting a Card To use a card as a Template Card all data saved in the card should be deleted 1 Select Menu User Format Card 2 Place the Template Card to format to the card reader 3 A window c...

Page 65: ...P IP port for the terminal The default value is 1470 4 Max Conn Sets the number of BioStar software that can be connected simultaneously Values 1 4 8 16 5 DHCP Sets whether or not to use DHCP protocol...

Page 66: ...to PC Connection and SIO Terminal Connection 1 Select Menu User Serial 2 RS485 PC Set whether or not to use RS485 communication between the terminal and a PC and the network speed between the terminal...

Page 67: ...nu Network USB Memory 2 Import In the window select a terminal ID of which data will be imported and click OK 3 Export After touching Export wait until the export is completed 4 Firmware Upgrade Selec...

Page 68: ...one of 4 wireless LAN settings Preset saved in advance through the BioStar software To set the Preset enter the SSID encryption type and encryption key through the BioStar software 1 Select Menu Netw...

Page 69: ...ing T A event key and entering the fingerprint 5 T A Key Finger Pin Authenticated by pressing the corresponding T A event key and entering the fingerprint and password Card Auth Mode 1 Select Menu Mod...

Page 70: ...ed after card or password authentication 3 Dual Authentication Set the Dual authentication mode Dual Authentication needs consecutive authentications from two different users for high security If the...

Page 71: ...he configuration Server matching works only with BioStar SE Standard Edition Please refer to BioStar user guide for detail 6 Match Timeout 5 10 15 20 25 30 Sets up the waiting time for Server Matching...

Page 72: ...minal the events can only be checked 1 Select Menu Mode T A Event 2 You can check the settings through the BioStar software Camera Event When a camera event occurs the camera will start recording when...

Page 73: ...an before Auto automatically determines the recognition speed according to the number of total fingerprint templates registered to the terminal 3 View Image Check whether or not to display the fingerp...

Page 74: ...relay for the door switch and then press OK Values Input 0 Input 1 Input 2 Input 3 SIO0 Input 0 SIO0 Input 1 SIO0 Input 2 SIO0 Input 3 SIO1 Input 0 SIO1 Input 1 SIO1 Input 2 SIO1 Input 3 SIO2 Input 0...

Page 75: ...Enter the video server port If you don t know server Port please ask your network administrator 4 VoIP Server IP If you have selected IP Interphone enter the VoIP server IP 5 VoIP Phone Number If you...

Page 76: ...sing and and then press OK 3 Time Sync You can use Time Sync in the server mode The terminal s time will be synchronized with the server time The time will be synchronized once every hour and only if...

Page 77: ...Touchkeypad Calibration 2 Set sensitivity of each of F1 F4 keys and the Call key Value 0 9 Note Generally the default value is recommended The factory default value is 4 Reset Reboots the BioStation T...

Page 78: ...ect whether or not to use the voice announcement You can change pre defined voice announcement by an event through BioStar Software 4 Menu Timeout If no key is pressed during the selected timeframe th...

Page 79: ...splayed 2 Select a desired log to view the details 3 The still image log is marked Event Log Still Image Log Log Search 1 Select Menu Log Log Search 2 Select a desired item among Start Date Start Time...

Page 80: ...ct Menu Log Delete All Log 2 Press OK to delete all saved logs Log Info 1 Select Menu Log Log Info 2 Check the number of logs saved in the terminal and the remaining available capacity Note You can sa...

Page 81: ...BioStation T2 User Guide http www supremainc com 80 5 Appendix...

Page 82: ...ce Communication Interface Ethernet WLAN RS485 x 1ch RS232 RS485 changeable x 1ch USB Wiegand IN OUT Switchable TTL I O 4 inputs Built in Relay 2 PoE Yes Hardware CPU 667Mhz RISC x 1 533MHz DSP x 1 Me...

Page 83: ...adapter which meets the specifications Current mA 1500 Switch Input VIH V TBD VIL V TBD Pull up Resistance 4 7K The input ports are pulled up with 4 7 K resistors Wiegand Output VOH V 5 VOL V 0 8 Pull...

Page 84: ...ble protection against harmful interference in a residential installation This equipment generates user and can radiate radio frequency energy and if not installed and used in accordance with the inst...

Page 85: ...ative font projects to support the font creation efforts of academic and linguistic communities and to provide a free and open framework in which fonts may be shared and improved in partnership with o...

Page 86: ...fied Versions may be sold by itself 2 Original or Modified Versions of the Font Software may be bundled redistributed and or sold with any software provided that each copy contains the above copyright...

Page 87: ...PARTICULAR PURPOSE AND NONINFRINGEMENT OF COPYRIGHT PATENT TRADEMARK OR OTHER RIGHT IN NO EVENT SHALL THE COPYRIGHT HOLDER BE LIABLE FOR ANY CLAIM DAMAGES OR OTHER LIABILITY INCLUDING ANY GENERAL SPE...

Page 88: ......

Reviews: