background image

19 

 

Table 5: Parts list, S

UPREME

 Advantage ECM 

 

Item 

Description 

Comments 

B04342 

Acoustic insulated 

  

B04343-04 

Side panel assembly 

Left panel and item 3 included 

B04340-02 

Side panel insulated 

  

B04344-02 

Back panel assembly 

  

B04341 

Top back insulated 

  

B04343-02 

Side panel assembly 

Right panel and 7 included 

B04340-01 

Side panel insulated 

  

B04302-01 

Top front panel 

  

B04312 

Breaker bracket 

  

10 

L01J005 

Breaker 50A 

  

11 

L01J004 

Breaker 25A 

  

12 

B04368 

Sequencer card assembly 

Card and plastic bracket 

13 

B03531-03 

Electronic card assembly 

  

14 

B03531-04 

Electronic card assembly 

  

15 

B04000-01 

Modify 12 positions terminal 

  

16 

X02333 

Label " Terminal Supreme A (ECM)" 

  

17 

B04313 

Support component 

  

18 

X50048 

Cosmetic "Supreme A" 3 breaker 

Supreme 23/25/27/30kw 

19 

X50047 

Cosmetic "Supreme A" 2 breaker 

Supreme 15/18/20kw 

20 

X50046 

Cosmetic "Supreme A" 1 breaker 

Supreme 10kw 

21 

L01L006 

Indicator light 

  

22 

L07F015 

Switch SPDT 

  

23 

L01J001 

Breaker 15amp 

  

24 

B04280 

Electrical sequencer kit 

Supreme 27/30kw 

25 

B04281 

Electrical sequencer kit 

Supreme 23/25kw 

26 

B04282 

Electrical sequencer kit 

Supreme 18/20kw 

27 

B04283 

Electrical sequencer kit 

Supreme 15kw 

28 

B04284 

Electrical sequencer kit 

Supreme 10kw 

29 

B04275 

Plastic top door 

  

30 

X50042 

Label logo Dettson 

  

31 

B04349 

Low door assembly 

  

32 

B04357-01 

Blower assembly 

Supreme 10 @ 25kw 1/2hp -ECM 

33 

B04357-02 

Blower assembly 

Supreme 20 @ 30kw 1hp -ECM 

34 

Z01I036 

Blower 112-9R 

  

35 

Z01I035 

Blower 112-8R 

  

36 

B01889 

Motor support band and legs 

  

37 

B03811-26 

Motor ass'y ECM 1/2 hp (prog) 

Supreme 10 @ 25kw 1/2hp -ECM 

38 

B03813-17 

Motor ass'y ECM 1 hp (prog) 

Supreme 20 @ 30kw 1hp -ECM 

39 

B04285 

Electrical blower kit 

  

40 

B03141-02 

Inductor 

  

41 

B04303 

Floor 

  

42 

Z04F004 

Paper filter 20x20x1 

  

43 

B04309 

Fan slide 

  

44 

B04304 

Fan separator 

  

45 

B03299-02 

Filter holder tip 

  

46 

B03298-02 

Contour filter support 

  

47 

R02N028 

Thermo 125+/-5.5C 

  

48 

B04308 

Hi-limit deflector 

  

49 

B04305 

Front separator 

  

50 

L01H030 

Relay DPST 22VDC 

  

51 

B04369 

Electrical power kit 

  

52 

B04351-02 

Element assembly 

5kw 

53 

B04351-01 

Element assembly 

4kw 

54 

B04315-01 

Element plate 

  

55 

L01F010 

Transformer 208/240/24 

  

56 

L99F007 

Terminal bloc 600V/175A (1423570) 

  

57 

L99F008 

Terminal bloc 600V/175A (1422570) 

  

58 

B04306 

Deflector 

  

59 

B04307 

Element support 

  

 

 

Accessories 

  

DFB-SUP 

  

Base for downflow 

(ref: B03310-03) 

 

Summary of Contents for SUP10-A240V12

Page 1: ...ial Boulevard Sherbrooke Quebec Canada J1L 1V8 Caution Do not tamper with the unit or its controls Call a qualified service technician INSTALLER SERVICE TECHNICIAN USE THE INFORMATION IN THIS MANUAL F...

Page 2: ...ng mode dehumidification 9 3 3 5 Electric heat heating mode 1 stage 9 3 3 6 Electric heat heating mode 2 stage 9 3 3 7 Heat pump heating mode single stage 9 3 3 8 Heat pump heating mode two stage 9 3...

Page 3: ...e Ask the technician installing your furnace to show and explain to you the following items i The main disconnect switch or circuit breaker ii The air filter and how to change it check monthly and cl...

Page 4: ...nstallation The return duct may be installed to the back to the bottom on the left side or on the right side of the unit The supply duct shall be installed on the top of the unit Care should be taken...

Page 5: ...installation must be performed with copper wire ONLY in order to comply with the Canadian electrical code The usage of an aluminum or copper wire is acceptable on models 25kW and lower Move all wires...

Page 6: ...er the vertical sections of the supply and return air duct with soundproofing material c Use baffles in short radius elbows d Use flexible hangers to suspend the ducts The SUPREME furnace is equipped...

Page 7: ...irflow and zero 0 ON delay programmed into the ECM motor that cannot be overridden Four 4 motor operation delay profiles are provided to customize and enhance system operation Refer to Figure 10 and F...

Page 8: ...heat pump When using a heat pump a thermostat with dial fuel option or a fossil fuel kit is required that prevents the operation of the electric elements and the heat pump at the same time Refer to t...

Page 9: ...ng mode 1 stage Thermostat closes circuit R to W1 or W2 Furnace delivers the selected electric heat airflow and maximum heating capacity is powered starting the heating elements in sequence with a del...

Page 10: ...igned to engage during the improper functioning of the blower or when the filter was improperly maintained 3 4 2 High limit verification After operating the furnace for at least 15 minutes restrict th...

Page 11: ...ler name and address START UP RESULTS Voltage Total current consumed by the elements Supply air temperature Return air temperature Supply air duct static pressure Return air duct static pressure Total...

Page 12: ...N Fan ON after delays at selected Cooling CFM OFF Compressor OFF Fan OFF after selected cooling delays ON Compressor ON Fan ON after delays at 80 of the selected Cooling CFM OFF Compressor OFF Fan OFF...

Page 13: ...2 6 0 5 2 6 0 5 2 6 0 5 2 6 0 5 2 6 0 Heating Elements Consumption 240V 208V Amp 41 4 35 9 62 1 53 8 75 8 65 7 82 8 71 8 96 5 83 6 103 5 89 7 82 8 71 8 96 5 83 6 103 5 89 7 113 6 98 5 124 3 107 7 Tota...

Page 14: ...Adjustment WHITE wire position ON Delay Time OFF Delay CFM Time 0 90 0 sec 100 90 sec 30 90 30 sec 100 90 sec 0 0 0 sec 0 sec ENH 30 sec 70 150 sec No adjustment required ON Delay Time OFF Delay CFM...

Page 15: ...575 1150 ON OFF DELAY Adjustment WHITE wire position ON Delay Time OFF Delay CFM Time 0 90 0 sec 100 90 sec 30 90 30 sec 100 90 sec 0 0 0 sec 0 sec ENH 30 sec 70 150 sec No adjustment required ON Del...

Page 16: ...16 Figure 15 Furnace dimensions...

Page 17: ...17 Figure 16 Electrical diagram SUPREME Advantage ECM...

Page 18: ...18 Figure 17 Parts list SUPREME Advantage ECM...

Page 19: ...3 25kw 26 B04282 Electrical sequencer kit Supreme 18 20kw 27 B04283 Electrical sequencer kit Supreme 15kw 28 B04284 Electrical sequencer kit Supreme 10kw 29 B04275 Plastic top door 30 X50042 Label log...

Reviews: